SYSTEM SPECIFICATIONS 

Model No. 

Rated Service 

Flow 

US GPM  (LPM) 

Max Flow Rate 

US GPM (LPM) 

Min. Well 

PUMP Flow 

Rate 

US GPM (LPM) 

Inlet / 

Outlet 

Drain 

Electrical 

Pressure 

Drop 

Operating 

Pressure 

Shipping 

Weight 

(lbs) 

CAFO 948 

3 (11.3) 

6 (22.7) 

5 (19) 

3/4" 

MNPT 

1/2" 

Hose 

110V 

AC 

< 15 

psig 

30 – 100 

psig 

82  

(63.5 Kg) 

 

 

Water Temp – 

4

 - 

38°C (39 - 100°F)

 

 

Water pH Range – 

6.8 to 8.5*

 

 

Max Raw Water Turbidity – 

5 NTU

 

 

Max Raw Water Iron – 

15 PPM

 

 

Alkalinity > 

[2 x (Sul Chlorides)]

 

 

Chlorine - 

Nil

 

 

Tannins  – 

Nil

 

 

Polyphosphates – 

Nil

 

 

Hydrogen Sulphide - 

Nil

 

 

Higher the pH, better the performance. If pH is lower than 6.8, call Rainfresh for information on ordering a pH Neutralizing Filter

 

 

(B)

 

HOW THE CAFO SYSTEM WORKS 

Your Rainfresh CAFO iron-removal filter utilizes oxidation and filtration technology to remove dissolved iron from water. 
This filter works by adding oxygen to the incoming water by passing it through a bubble of compressed air which oxidizes 
the ferrous iron to a filterable rust form (ferric iron). The water is then passed through a special filter bed which acts as a 
physical barrier to trap iron precipitate. As more water passes through this iron filter, the oxygen in the unit is used up, and 
the media gets loaded with iron. The automatic backwash process then replenishes the supply of oxygen, and flushes away 
the precipitated iron trapped in the media bed. 

The backwash process is completely automatic and is factory set for 12:00 AM (can be changed). 

Note: 

No salt or chemicals are required to clean the system. As such it is typically safe to dump the water into the septic 

system. However, because in every backwash cycle, about 60 gallons of water are used to clean the system, it is 
recommended that you consult a professional to ascertain the safety of the water going into your septic system. 
  

(C)

 

SAFETY PRECAUTIONS

 

 

-

 

Follow all applicable province/state and local regulations.  

-

 

Handle the filter carefully. Do not lie on side, turn upside down, drop or drag. 

 

CAUTIONS BEFORE INSTALLATION 

 

Follow all plumbing codes for installation. 

 

To operate properly, the well pump flow rate must exceed the backwash flow rate (4.5 US GPM (17 LPM)). If your 
well pump does not deliver this flow rate, do not install the unit as it will not work properly. You may need to either 
change the well pump or call Rainfresh for a custom size unit that will operate within your pump specifications. 

 

The automatic control valve works on 110V AC. We recommend a GFI (ground fault interrupter) 120 volt outlet 
within 5 feet of the filter. Extension cords are not recommended.  

 

CAFO systems do not kill or remove bacteria or any other pathogenic microorganisms. To continuously disinfect all 
the water in your house, we recommend that you install a Rainfresh UV system. Call Rainfresh for details. 

 

For use on cold water only. 

 

 

Only use thread seal tape 

(Teflon® tape)

 

for fitting connections into unit. 

DO NOT USE pipe dope or chemical 

sealants. 

 

 

If water pipes are used to ground electrical system, install jumper wire

 

(#4 gauge solid copper wire) across the unit 

to maintain proper grounding of your electrical system 

 

Protect your unit from freezing 

- drain the unit if freezing temperatures exist.

 

 

Do not use petroleum based lubricants 

on O-rings as they will cause swelling and result in water leakage. 

 

NOTE: IF SOLDER TYPE FITTINGS ARE USED DO NOT USE torch near inlet/outlet connections. 

All solder joints 

should be made before joining pipe to filter head.  

 

DO NOT over-tighten 

metal fittings on to unit connections.  

Summary of Contents for CAFO 948

Page 1: ...ne Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS A System Specifications 2 B How the CAFO System Works 2 C Safety Precautions 2 D Installation 3 a...

Page 2: ...er are used to clean the system it is recommended that you consult a professional to ascertain the safety of the water going into your septic system C SAFETY PRECAUTIONS Follow all applicable province...

Page 3: ...plete a cycle from start to shut off Well pump flow rate Volume of water collected drawdown Time for pump cycle x 60 EXAMPLE If you collect 5 gal of water and the pump takes 40 seconds to complete a c...

Page 4: ...m but it is recommended that you check your local plumbing codes Copper and PVC CPVC and PEX are the most popular The system has 3 connections an inlet an outlet and a drain line connection If you are...

Page 5: ...nto the open end of the bypass valve and lock them in by inserting the red locking clips into the slots Fig 5 For ease of installation orient the inlet outlet fittings in the direction of the inlet ou...

Page 6: ...on all the way If you have no leaks proceed to the next steps Connect the control valve to the AC power source Fig 9 Manually put the CAFO filter into the BACKWASH cycle by pressing the REGEN button s...

Page 7: ...ve Mode 11 Valve ID The control valve has a display screen and 4 buttons PROGRAMMING I LANGUAGE SELECTION SETTINGS The function of this key is to enter the level one programming mode where the valve s...

Page 8: ...nt minutes TIME OF DAY 08 51 PM TIME OF DAY 08 51 PM 7 Press SETTINGS key again and AM PM will be highlighted 8 Now press UP or DOWN key to change AM PM value to current time 9 Press SETTINGS button a...

Page 9: ...is setting unless you want to change all your settings to factory settings PROGRAMMING COMPLETE 18 Press SETTINGS again and this completes the programming Unlock display by pressing SETTINGS for 3 sec...

Page 10: ...s valve located at the back of the control see Fig 3 To resume filtered water service open bypass valve by rotating the knobs counterclockwise G MAINTENANCE The CAFO948 filter does not require any rou...

Page 11: ...e 6 Supply water pH too low 1 Plug in control valve to power supply 2 Open bypass valve 3 Check if riser is cracked or O ring is damaged Replace faulty parts 4 Replace valve seals spacer and piston as...

Page 12: ...12 I PARTS LIST Valve body Power head...

Page 13: ...13 To order replacement parts Call 1800 667 8072 Monday to Friday 8 00 AM to 5 PM EST...

Page 14: ...m the Warrantor This warranty does NOT cover and is intended to exclude any liability on the part of Envirogard for any incidental damages consequential damages labour charges or any other costs incur...

Reviews: