background image

5

ATTACH STRAIGHT WAND TO  THE TOP 

CURVED WAND:

Push  soft  end  of  the  Rainbow  hose  over 

raised  ridge  on  curved  handle  wand  with 

airfl ow sleeve until it “SNAPS” into place.

ASSEMBLE

THE WANDS

6

  CONNECT  STRAIGHT  WAND  AND 

CURVED HANDLE WAND:

Connect straight wand and curved handle 

wand  by  aligning  the  button  lock  on  the 

curved wand handle with the guide on the 

wand collar and sliding together.

7

  CONNECT THE STRAIGHT WAND AND 

THE BOTTOM CURVED WAND:

Connect the straight wand and the bottom 

curved  wand  (with  fl oor  and  wall  tool 

attached) using the above steps.

8

ADJUST AIRFLOW CONTROL SLEEVE:

Adjust the airfl ow control sleeve on top of 

curved  wand.  Close  opening  with  airfl ow 

control  sleeve  for  full  power.  To  reduce 

airfl ow,  rotate  airfl ow  control  sleeve  so 

opening in curved wand is exposed. Adjust 

as needed for different cleaning jobs.

5

TROUBLE-

SHOOTING

NOTE:

If the above solutions do 

not prove successful, 

call your Authorized 

Rainbow Distributor.

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

Machine 

Won’t Run.

Air inlet screen is plugged 

with debris.

Clean off debris thoroughly.

Not fi rmly plugged in.

Plug unit in fi rmly or try 

another outlet.

Rainbow not properly latched 

to water basin.

Ensure side latches of water 

basin are locked.

Automatic resetting motor 

protector has tripped.

Turn Rainbow off. Leave 

off for two seconds. Turn 

Rainbow back on.

Defective cord, switch 

or machine.

Call  your Rainbow Distributor 

or Rainbow Service Center.

Loss of Airfl ow.

Machine not correctly 

positioned on water basin.

Ensure machine is properly 

seated and latched onto 

water basin.

Plugged hose, wand 

attachment or Power Nozzle.

Remove obstruction from 

clogged area.

Incorrect airfl ow control 

sleeve setting.

Adjust airfl ow control sleeve 

setting on curved wand.

HEPA Neutralizer needs 

servicing or replacement.

Remove HEPA Neutralizer 

and clean or replace.

Machine is running on 

low speed.

Turn power switch to 

high speed.

Separator is clogged or dirty. Remove separator and clean.

Discharges Dust.

Low level of water in basin.

Fill water basin to 

correct level.

Excessively dirty water 

in basin.

Replace with clean water.

Hole in HEPA Neutralizer.

Call your Rainbow Distributor 

or Rainbow Service Center 

for replacement.

Heavy Foaming 

of Water in 

Water Basin.

Soapy contaminant in 

water basin.

Replace with clean water.

High level of water in basin.

Empty water basin and refi ll to 

correct level.

Musty Odor.

Water basin not cleaned or 

dumped after use.

Clean water basin and use 

Deodorant Air Freshener 

while cleaning.

Separator clogged or dirty.

Remove separator and clean.

Damp HEPA Neutralizer.

Refer to page 8.

Machine stored on 

water basin.

Do not store machine on 

water basin.

Machine 

Running Hot, Hot 

or Burnt Odor.

Plugged hose, wand, 

attachment or Power Nozzle.

Remove obstruction from 

clogged area.

Machine not sealed on water 

basin properly.

Ensure machine is properly 

seated and latched onto 

water basin.

Different 

Tone, Noise or 

Vibration.

Separator clogged or dirty.

Remove separator and clean.

Water level is above center 

dome in water basin.

Empty water basin and refi ll to 

correct level.

10

Summary of Contents for E2

Page 1: ...should rst contact the Distributor or Dealer from whom you purchased your Rainbow If you have any problem locating that person contact Rexair s Customer Service Department at the address listed below...

Page 2: ...________________________________________ City State Zip __________________________________________________________________________________________________________ Phone _______________________________...

Page 3: ...equipped with an interlock switch that prevents the unit from operating if the water basin is not properly latched DO NOT ATTEMPT TO OVERRIDE THIS SAFETY FEATURE 14 WARNING To avoid risk of electric s...

Page 4: ...izer protector and reconditioner for ease of operation and superior cleaning results One quart OPTIONAL ACCESSORIES FOR YOUR RAINBOW WARNING To reduce the risk of electrical shock do not use motorized...

Page 5: ...the air intake until it clicks To remove press both latches and pull hose from machine 4 CONNECT ELECTRICAL CORD TO WALL OUTLET Connect the electrical cord to wall outlet Toggle the switch forward to...

Page 6: ...r Loss of Air ow Machine not correctly positioned on water basin Ensure machine is properly seated and latched onto water basin Plugged hose wand attachment or Power Nozzle Remove obstruction from clo...

Page 7: ...e brush in warm soapy water and replace when dry beaded edge of guard up DUSTING BRUSH Clean in warm soapy water and let dry UPHOLSTERY TOOL Whisk clean with the open end of the Rainbow hose while Rai...

Page 8: ...maintain the proper humidity Deodorizer Aromatizer By adding a few drops of your favorite Rainbow fragrance Deodorizer Aromatizer By adding a few drops of your favorite Rainbow fragrance Deodorizer A...

Reviews: