ESP-LXIVM Series Controllers
Set FloZone Rates
Turn the controller dial to Flow Sensor
A
At the FLOW SENSOR screen, with Set Flow Rates selected, press
Next.
B
At the Set Flow Rates screen, press the Down Arrow key to select
Set FloZone Rates, then press Next.
A
FLOW SENSOR
Next
Current Flow Reading
Set Flow Units
Set FloWatch
Set FloManager
Set Flow Rates
B
Set Flow Rates
Next
View Flow Rates
Clear Flow Rates
Set FloZone Rates
Set Station Rates
Learn Flow
C
The Set FloZone Rates information screen appears; press Next.
D
At the Set FloZone Rates screen, press the + and – keys to choose
the desired FloZone (from 1-10).
C
Set FloZone Rates
Next
These rates are used
by FloManager.
The zone rate cannot
highest station rate.
be set lower than the
D
Set FloZone Rates
Below 1000.0
FloZone
001
Max GPM
0000.0
FS(s) 1
MV(s) 1
Do not set rate
Done
E
Press the + and – keys to set the Max GPM for that FloZone. Press
the Arrow keys to navigate between the number setting fields.
• Press and HOLD keys to accelerate settings.
NOTICE
Maximum FloZone flow rates are used only by Flo-Manager®.
FloWatch is unaffected by user-entered FloZone flow rates.
E
FloZone Flow Rates
FloZone
Max GPM
Sensor(s) 1
MV(s)
1
010.5
1
H
Repeat this process to manually set up Flow Rates for additional
FloZones as desired.
After Flo-Manager® is enabled and station and/or FloZone flow rates
are entered, Flo-Manager® works automatically in the background
to run stations based on available hydraulic capacity
B
NOTE: Flo-Manager® can be used with or without flow sensing
hardware. If flow sensors are not present it will rely on manu-
ally entered information; if flow sensors are present it will rely
on Learned Flow information, which is typically more accurate.