Rain Bird ESP-4Si Installation & Operation Manual Download Page 5

4

Fill Out Program Schedule Sheet

Before you begin programming, fill out the ESP
Controller Program Sheet and attach it to the label on the
inside of the controller door. A sample Program Sheet is
shown in this illustration.

Ê

 Enter a brief description of each station on the con-

troller.

Ë

 In the Program A column, mark the watering schedule.

Either circle one of the fixed intervals, or fill in the wa-
tering days in the “Custom” row.

Ì

 Enter the starting time(s) for Program A. You may

have up to three separate start times for each pro-
gram.

Í

 Enter the run time for each station assigned to Pro-

gram A. Enter “0” for stations that are not used in Pro-
gram A.

Î

 Repeat steps 2 - 4 for Program B. If you are using a

fixed schedule, Program B will have the same water-
ing days as Program A.

Ž

ESP Controller
Program Sheet

Œ

Select Watering Schedule

The ESP-Si has two types of watering schedules, either
fixed or custom. The fixed schedule sets watering to oc-
cur every second, third, or fifth day. The custom sched-
ule lets you select specific days of the week on which
watering is to occur.

The type of schedule you select applies to both pro-
grams, A and B. For example, you cannot set Pro-
gram A to a fixed schedule and Program B to a cus-
tom schedule.

Ê

 To use a fixed schedule, move the Schedule Slide

Switch to one of the FIXED positions:
2 = every other day
3 = every third day
5 = every fifth day

Ë

 To use the custom schedule, move the Schedule Slide

Switch to the “C” position.

ESP-6Si

FIXED

CUSTOM

SCHEDULE

2       3       5      C

ESP-6Si

FIXED

CUSTOM

SCHEDULE

2       3       5      C

Œ

This Manual: http://www.manuallib.com/file/2721363

Summary of Contents for ESP-4Si

Page 1: ...From ManualLib com ManualLib com collects and classifies the global product instrunction manuals to help users access anytime and anywhere helping users make better use of products Home http www manu...

Page 2: ...u want to Change the time of day page 5 Turn the controller off and on for example because of rain page 9 Adjust watering times for all stations for example during a hot or cool period page 8 Start th...

Page 3: ...ls include LCD Display during normal operation displays the time of day during programming shows the results of your commands during watering shows the station that is running and the minutes remainin...

Page 4: ...t to Program A with 10 minutes of run time per station The default starting time is 8 00 AM The default program will water every day if the Schedule Slide Switch is set to Custom If the Schedule Slide...

Page 5: ...are using a fixed schedule Program B will have the same water ing days as Program A ESP Controller Program Sheet Select Watering Schedule The ESP Si has two types of watering schedules either fixed o...

Page 6: ...urrent Day Setting the current day varies somewhat depend ing on whether you are using a custom schedule or a fixed schedule Custom Schedule Make sure the Schedule Slide switch is set to C Turn the di...

Page 7: ...ay Program B on Tuesday Thursday and Saturday If you are using a fixed watering schedule both programs will have the same ON days For ex ample if you are using the three day fixed sched ule Program A...

Page 8: ...TO WATER CUSTOM SCHEDULE MIN HR DAY 3 2 1 6 5 4 3 2 1 SUN SAT FRI THU WED TUE MON ESP 6Si FIXED CUSTOM SCHEDULE 2 3 5 C Set Station Run Times Turn the dial to Station 1 vThe display shows the selected...

Page 9: ...inate a start time press or until the blank setting between 11 45 PM and 12 15 AM appears If you want to set additional start times for this program move the dial to 2 or 3 in the Watering Start Times...

Page 10: ...The display will show the current day and time In addition the right hand minute digit will blink to show that the con troller has been turned off The OFF setting can be used during rainy weather sea...

Page 11: ...rams Turn the dial to ADJUST WATER The display shows the current water budget set ting between 10 and 200 A setting of 100 means that all stations will run according to their normal programmed run tim...

Page 12: ...m that will run each station in sequence for two min utes You can use this program to check out the operation of all the sprinklers in the system Turn the dial to AUTO Press both arrow buttons at the...

Page 13: ...clips and replace it with a 1 0 AMP 250 Volt FAST BLO fuse To reinstall the face panel align the rounded posts on the inside of the panel with the sleeves inside the cabinet Also align the Schedule Sl...

Page 14: ...or hole B only for an exposed stud When the wide flat end of the spacer is pressed against the wall or stud the screw is at the proper depth Do not drive a fastener into location D at this time Remove...

Page 15: ...each wire to make sure it s securely connected Station Valve Wiring Connect each valve by its own separate power wire to one of the numbered terminals on the ESP Si flip strip as shown in the illustr...

Page 16: ...tion for several days without power If electrical power to the ESP Si remains uninterrupted the lithium coin cell will last well over one year However long or frequent power interruptions will cause f...

Page 17: ...ferral 4 Power is off to the ESP Si and the backup battery has run down Re establish power to the controller and then reprogram it Re place the battery with a 3 Volt lithium coin cell Display shows nu...

Page 18: ...he following measures 1 Reorient the receiving antenna 2 Move the controller away from the receiver 3 Plug the controller into a different outlet so that the controller and receiver are on different b...

Reviews: