Rain Bird ESP-4Si Installation & Operation Manual Download Page 10

9

Turn Controller On and Off

Œ

To set the controller to automatic operation, turn

the dial to AUTO. The display will show the cur-
rent day and time until the next scheduled auto-
matic start. When a program is running, the dis-
play will show the station currently turned on
and the minutes remaining on its run time.
When the entire program is complete, the dis-
play will change back to the current day and
time.

If you forget to turn the dial to AUTO, the con-
troller will eventually set itself to automatic op-
eration. The only setting that prevents auto-
matic operation is OFF (see step 2).

To turn the controller off and prevent all water-

ing, set the dial to OFF. The display will show
the current day and time. In addition, the right-
hand minute digit will blink to show that the con-
troller has been turned off.

The OFF setting can be used during rainy
weather, seasonal shutdown, or system mainte-
nance.

OPERATING THE CONTROLLER

ON

OFF

A

B

MAN

START

 ADV.

OFF

AUTO

ADJUST WATER %

CURRENT TIME

AND DAY

WATERING

START TIMES

WATERING TIME PER STATION

DAYS TO WATER

CUSTOM

SCHEDULE

MIN

HR

DAY

3

2

1

6

5

4

3

2

1

SUN

SAT

FRI

THU

WED

TUE

MON

PGM

A

DAY

ESP-6Si

FIXED

CUSTOM

SCHEDULE

2       3       5      C

AM

Œ

ON

OFF

A

B

MAN

START

 ADV.

OFF

AUTO

ADJUST WATER %

CURRENT TIME

AND DAY

WATERING

START TIMES

WATERING TIME PER STATION

DAYS TO WATER

CUSTOM

SCHEDULE

MIN

HR

DAY

3

2

1

6

5

4

3

2

1

SUN

SAT

FRI

THU

WED

TUE

MON

PGM

A

DAY

ESP-6Si

FIXED

CUSTOM

SCHEDULE

2       3       5      C

AM

Technical Support:1-800-RAIN BIRD

This Manual: http://www.manuallib.com/file/2721363

Summary of Contents for ESP-4Si

Page 1: ...From ManualLib com ManualLib com collects and classifies the global product instrunction manuals to help users access anytime and anywhere helping users make better use of products Home http www manu...

Page 2: ...u want to Change the time of day page 5 Turn the controller off and on for example because of rain page 9 Adjust watering times for all stations for example during a hot or cool period page 8 Start th...

Page 3: ...ls include LCD Display during normal operation displays the time of day during programming shows the results of your commands during watering shows the station that is running and the minutes remainin...

Page 4: ...t to Program A with 10 minutes of run time per station The default starting time is 8 00 AM The default program will water every day if the Schedule Slide Switch is set to Custom If the Schedule Slide...

Page 5: ...are using a fixed schedule Program B will have the same water ing days as Program A ESP Controller Program Sheet Select Watering Schedule The ESP Si has two types of watering schedules either fixed o...

Page 6: ...urrent Day Setting the current day varies somewhat depend ing on whether you are using a custom schedule or a fixed schedule Custom Schedule Make sure the Schedule Slide switch is set to C Turn the di...

Page 7: ...ay Program B on Tuesday Thursday and Saturday If you are using a fixed watering schedule both programs will have the same ON days For ex ample if you are using the three day fixed sched ule Program A...

Page 8: ...TO WATER CUSTOM SCHEDULE MIN HR DAY 3 2 1 6 5 4 3 2 1 SUN SAT FRI THU WED TUE MON ESP 6Si FIXED CUSTOM SCHEDULE 2 3 5 C Set Station Run Times Turn the dial to Station 1 vThe display shows the selected...

Page 9: ...inate a start time press or until the blank setting between 11 45 PM and 12 15 AM appears If you want to set additional start times for this program move the dial to 2 or 3 in the Watering Start Times...

Page 10: ...The display will show the current day and time In addition the right hand minute digit will blink to show that the con troller has been turned off The OFF setting can be used during rainy weather sea...

Page 11: ...rams Turn the dial to ADJUST WATER The display shows the current water budget set ting between 10 and 200 A setting of 100 means that all stations will run according to their normal programmed run tim...

Page 12: ...m that will run each station in sequence for two min utes You can use this program to check out the operation of all the sprinklers in the system Turn the dial to AUTO Press both arrow buttons at the...

Page 13: ...clips and replace it with a 1 0 AMP 250 Volt FAST BLO fuse To reinstall the face panel align the rounded posts on the inside of the panel with the sleeves inside the cabinet Also align the Schedule Sl...

Page 14: ...or hole B only for an exposed stud When the wide flat end of the spacer is pressed against the wall or stud the screw is at the proper depth Do not drive a fastener into location D at this time Remove...

Page 15: ...each wire to make sure it s securely connected Station Valve Wiring Connect each valve by its own separate power wire to one of the numbered terminals on the ESP Si flip strip as shown in the illustr...

Page 16: ...tion for several days without power If electrical power to the ESP Si remains uninterrupted the lithium coin cell will last well over one year However long or frequent power interruptions will cause f...

Page 17: ...ferral 4 Power is off to the ESP Si and the backup battery has run down Re establish power to the controller and then reprogram it Re place the battery with a 3 Volt lithium coin cell Display shows nu...

Page 18: ...he following measures 1 Reorient the receiving antenna 2 Move the controller away from the receiver 3 Plug the controller into a different outlet so that the controller and receiver are on different b...

Reviews: