8
ESP-LX+ & LXi+ Installation, Programming, & Operation Guide
Fill Out Programming Chart
Before you begin programming, fill out the Programming Chart
and attach it to the inside of the controller door. A sample
Programming Chart is shown on page 9. Follow these instruc-
tions to complete the chart.
➊
Describe the sprinklers or plant zones covered by each
station on the controller.
➋
Indicate which stations drive a master valve or booster
pump relay by checking ON in the MV / Pump column.
(See page 26 for more information).
➌
In the Program A column, for Custom cycle, circle the
specific days of the week; for Cyclical schedule, write the
cycle period (e.g., 3-day cycle means every third day);
for ODD/EVEN-day watering, check ODD or EVEN.
➍
Enter the start time for Program A. You may enter up to six
start times for each program, but only one is needed to run
the program.
NOTE
: Start times apply to the program,
not
to the
individual stations assigned to the program. In this
example, Program A begins watering at 8:00 a.m. on
Mondays, Tuesdays, Thursdays, and Saturdays.
Station 1 runs for ten minutes, followed by Station 2
for 20 minutes, Station 3 for 20 minutes, and Station 4
for 5 minutes. The entire program takes about an
hour.
➎
Enter the watering run time (in hours and minutes) for each
station assigned to Program A.
➏
Enter the water budget percentage by program. The water
budget for sample Program A is set to 80%.
➐
Enter the station delays for Program A. A station delay is
the time between the end of one stations operation and
the beginning of the next. Use a station delay to let a water
well recover or to allow slow-closing valves to turn off
completely. If neither of these situations applies to your
site, leave the station delay set to 0. A station delay setting
applies to all stations in the program.
In the sample chart, Program A has a one-minute delay
between stations. When Station 1 ends, the controller waits
one minute before starting Station 2. There will also be a
one-minute delay between Station 2 and Station 3, etc.
➑
Make any special notes in the space provided.
➒
Repeat steps 2 through 7 for Programs B, C, and D.
NOTE
: Stations assigned to Program D cannot be
used in any other programs. See page 19 for more
information.
Summary of Contents for ESP-12LX+
Page 6: ...3 ESP LX LXi Installation Programming Operation Guide Station Layout...
Page 12: ...9 ESP LX LXi Installation Programming Operation Guide F or E S P LX a nd LX i C on trollers D...
Page 50: ...47 ESP LX LXi Installation Programming Operation Guide...
Page 52: ...49 ESP LX LXi Installation Programming Operation Guide...
Page 72: ...69 ESP LX LXi Installation Programming Operation Guide NOTES...