4/8/2013

Voltage Monitor – Instruction Manual 
Model 520603-2V150

 

 

P/N 520603-
2V150 

REV. B  9/11 

© 2011 RAILWAY EQUIPMENT CO. 

 

5

                                clear. 
 
                                

HI AMP 

                                COUNT ___ - 

High amperage incidents on Channel 2.  Press 

DECREASE 

to 

                                Clear. 
 
                                

LOW AMP 

                                COUNT ___ - 

Low amperage incidents on Channel 2.  Press 

DECREASE 

to clear. 

 

                             
 

                   2.1.3 Push Buttons 

 

Below the digital display are three control push buttons: 

INCREASE – 

This is used to increase the value of the displayed parameter, if enabled. 

DECREASE – 

This button will decrease the value of the displayed parameter, if 

enabled. 

MODE –

 This control is used to increment through the available screens. 

2.1.4 LED Status Indicators 

 
Two LEDs are used to indicate Channel OK, one for each input channel. 

2.1.5  External Wiring Connector 

Near the bottom of the front panel there is a twelve position socket with a removable 

connector for external wiring.  The connection locations are shown below: 

 

PIN        CONNECTION                                                          INPUT NUMBER 

1            INPUT 10-48 VDC                                                     # 1 +VOLTAGE 

2            COM 0V                                                                     # 1 -VOLTAGE 

3            NORMALLY CLOSED                                               # 1 OUTPUT RELAY       

4            FUSED COMMON                                                    # 1 OUTPUT RELAY 

5            NORMALLY OPEN                                                   # 1 OUTPUT RELAY 

6            NO CONNECTION 

7            NO CONNECTION 

8            INPUT 1-150 VDC                                                    # 2 + VOLTAGE 

9            COM 0V                                                                   # 2 – VOLTAGE 

10          NORMALLY CLOSED                                              # 2 OUTPUT RELAY 

11          FUSED COMMON                                                    # 2 OUTPUT RELAY 

12          NORMALLY OPEN                                                  # 2 OUTPUT RELAY     

Summary of Contents for 520603-2V150

Page 1: ...ree standing unit that features the ability to monitor two DC voltage sources and has optional temperature and current monitoring ability CRAGG RAILCHARGER Instruction Manual for Digital Voltage Monit...

Page 2: ...ii Contents 1 0 WARNINGS CAUTIONS AND NOTES 1 2 0 OPERATION 2 2 1 Front Panel Features and Components 2 2 1 1 Figure 1 Front Panel of Voltage Monitor 3 2 1 2 Digital Display 3 2 1 3 Push Buttons 5 2...

Page 3: ...fore proceeding Table 1 Warnings Cautions and Notes Symbol Description WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicate...

Page 4: ...e fuse Channel two has a voltage range of 1 to 150 VDC but is only available for use if channel one is powered There is 2 500 volts isolation between channels The monitor has easy front panel access f...

Page 5: ...y will change state and the channel one CHANNEL OK LED will go out Factory default is 50 0 VDC LOW VCH1 SET __ _ Low voltage setpoint for channel one adjustable from 0 to 50 0 VDC If the input voltage...

Page 6: ...screen will display the software revision level installed on the monitor The addition of the temp probe adds the following screens HIGH TEMP SET ___ Temperature setting above which channel two relay w...

Page 7: ...if enabled MODE This control is used to increment through the available screens 2 1 4 LED Status Indicators Two LEDs are used to indicate Channel OK one for each input channel 2 1 5 External Wiring C...

Page 8: ...current level can be used to trigger a fault condition on channel two either independently or in conjunction with channel two voltage and or with the temperature sensor described in 2 1 7 2 1 7 TEMPE...

Page 9: ...attery Voltage Monitor with Relay Outputs For Lead Acid and NiCad Batteries Programmable Voltage Parameters LED Status Indicators Digital Amperage Meter when optional Amp Probe is used Digital Voltage...

Page 10: ...DC Channel 1 and 2 sensitivity is 100 MV per step The inputs are protected against reverse polarity The input power is protected by an internal resettable fuse The monitor outputs are form C relay wit...

Reviews: