background image

5

RailKing 4-6-2 K-4 Steam Engine

Speed Control:  

M.T.H. engines equipped with Loco-Sound have speed control capabilities that
allow the engine to maintain a constant speed up and down grades and around
curves, much like an automobile cruise control.  You can add or drop cars on
the run, and the engine will maintain the speed you set. 

While the engine is programmed to start with the speed control feature
activated, you can opt to turn it off.  This means the engine’s speed will fall as
it labors up a hill and increase as it travels downward.  It is also affected by the
addition or releasing of cars while on the run. 

To turn speed control on and off,

 put the engine in neutral, then press the

transformer’s Whistle button firmly but quickly one time then immediately
press the Bell button two times.  Repeat the 1 whistle, 2 bells code to return it
to the other state.  

You will want to do this during the initial neutral upon

start-up if you ever couple this engine to another engine that is not
equipped with speed control to avoid damaging the motors in either
engine.

  Each time you shut down the engine completely, it will automatically

turn speed control on.

Direction Lock:

You can lock your engine into a directional state (forward, neutral, or reverse)
so that it will not change directions.  To do this, put the engine into the
direction you want or into neutral, to lock it into neutral, run it at a very slow
speed (< 10 scale mph), and quickly but firmly press your transformer’s
Whistle button once followed immediately by three presses of the Bell button. 
The engine will not change direction (including going into neutral) until you
repeat the 1 whistle, 3 bells code to return the engine to its normal state.

Feature to Be Activated:

Speed Control On/Off
Lock into a Direction/Unlock

Button Code:

1 Whistle, 2 Bells
1 Whistle, 3 Bells

Summary of Contents for RAILKING 4-6-2 K-4 STEAM ENGINE

Page 1: ...lity chart on page 14 and is completely compatible with most other 3 rail locomotives rolling stock and accessories M T H takes pride in manufacturing high quality products like your RailKing steam en...

Page 2: ...Proto Dispatch 6 Volume Control 7 Maintenance 8 Lubrication and Greasing Instructions 8 Cleaning the Wheels Tires and Track 9 Locomotive Traction Tire Replacement 9 Smoke Unit Maintenance 10 Locomoti...

Page 3: ...s and linkage components and pickup rollers to prevent them from squeaking Lightly grease the outside idler and drive gears marked G in Fig 3 on page 8 to prevent them from squeaking Use light househo...

Page 4: ...ontinue to ring from the time your turn it on until you press and release the button again to turn it off Direction Your train is programmed to start in neutral To put the engine into forward and then...

Page 5: ...istle 2 bells code to return it to the other state You will want to do this during the initial neutral upon start up if you ever couple this engine to another engine that is not equipped with speed co...

Page 6: ...ape player to connect your microphone to the remote lock on To use Proto Dispatch simply plug the mini cable into the microphone and into the Mic port on the left side of the remote lock on and speak...

Page 7: ...ounds made by this engine turn the master volume control knob located under the engine clockwise to increase the volume and counter clockwise to decrease the volume see Fig 1 Proto Sound 2 0 Volume Ad...

Page 8: ...s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first To access the gear box do the following Unscrew...

Page 9: ...and denatured alcohol not rubbing alcohol Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on the rails Traction Tire Replacem...

Page 10: ...enjoy trouble free smoke unit operation for years When preparing to run this engine add 15 20 drops of smoke fluid through the smokestack see Fig 4 We recommend M T H ProtoSmoke Seuthe LGB or LVTS fl...

Page 11: ...plate away and inspect the wick If it is darkly discolored and hard it should be replaced You can obtain replacement parts directly from the M T H Parts Department Locomotive Light Bulb Replacement T...

Page 12: ...when I press the bell button You may be pressing the button too quickly Try pressing the whistle button more slowly taking approximately one full second to fully depress the button You may be pressing...

Page 13: ...tubular track It is also compatible with virtually any standard AC transformer See page 14 for a complete list of compatible transformers and wiring instructions Volume Remedy The sounds seem distort...

Page 14: ...t Standard Lionel1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Right Terminal Electronic Lionel LW A U 8 18v 75 Watt Stan...

Page 15: ...en using electrical products basic safety precautions should be followed including the following Read this manual thoroughly before using this device M T H recommends that all users and persons superv...

Page 16: ...e address daytime phone number a copy of your sales receipt the Return Authorization number and a full description of the problem must be included to facilitate the repairs Please include the descript...

Reviews: