39
Fault
Remedy
Running speed of the engine too low.
Check running speed of the engine (see technical
specifications).
Low-pressure nozzle /4/ is fitted.
Fit high-pressure nozzle /4/.
Nozzle /4/ blocked/eroded.
Clean/replace nozzle /4/.
Intake filter /31/ contaminated.
Clean intake filter /31/.
Air in the system.
Bleed the appliance (see "Use").
Water supply quantity too low.
Check water supply (see technical specifications).
Supply lines to high-pressure pump /39/
leaking or blocked.
Check all supply lines to high-pressure pump /39/.
Appliance is leaking, water dripping from under appliance
■ The high-pressure pump /39/ is leaking.
NOTE
► Max. permissible is 3 drops per minute.
For more serious leaks, have the appliance checked by
customer service.
CLEANING AGENT IS NOT DRAWN IN
Fault
Remedy
High-pressure nozzle /4/ is fitted.
Fit low-pressure nozzle /4/.
Cleaning agent hose /11/ leaking or
blocked.
Inspect/clean cleaning agent hose /11/.
► If the fault cannot be remedied, the appliance must be checked by customer service.