4.7. In case of damage due to operation of the pump dry,
the security lapse.
4.8. Filling the pump with water (bleeding). Open for pouring
stopper (4) and pour water while pumping chamber is not filled.
Must merge enough water to fill the entire intake manifold and
the turbine chamber to the pump. If despite your efforts pumping
chamber is not filled, this means that non-return valve (1)
mounted at the bottom of the inlet pipe is not in working order
and must be replaced.
4.9. After filling the pump with water dispensers Screw
stopper (4).
4.10. To be perfect is an important force-suction tube is
mounted in a vertical position for at least 50 centimeters before
placing the knee. If using a flexible tube (similar to garden hose)
at the place suction hose in a vertical position at least 70 cm (see
diagram A).
4.11. All joints and connections on suction and Injection
piping must be firm, precise and tight checked for leaks. Check
carefully the connection of pipes to pump. Poor associated
piping can lead to falling of air into the system, which can disrupt
proper operation of the pump.
5. Turn the pump. Insert the plug of the power cord into
the outlet. Do not let the pump operate in a closed floodgate
of Injection piping. Open all interlocks, are in force-pipeline
(valves, valves, etc.).. Turn the pump through the switch. After
use, turn off the pump through the switch.
6. Support and maintenance. Before starting maintenance
work and maintenance, the pump should be excluded from the
network. Pull the plug of the power cord from the outlet.
6.1. Wash the pump. After working with pools of water
containing chlorine or liquid, leaving sediment, the pump must
be washed with clean water.
6.2. Removal of blockages. Remove suction tube from the
pump inlet. Connect the hose to the conduit through the body
and allow the pump to run water until you remove the pollution.
Before re-commissioning of the pump can check whether it is
idling through a short integration.
6.3. Frost protection. Protect pump from freezing. To this
end, unscrew the stopper for the drain (5) at the bottom of the
pump nozzle into a suction tube. At very low temperatures,
removing the pump and store in a safe place.
6.4. You should always vent to the motor free.
6.5. If necessary, repair your pumps and power is best
carried out only by qualified specialists in workshops RAIDER,
which used only original spare parts. Thus ensuring their safe
operation.
7. Environmental protection.
In order to protect the environment electrical machinery,
appliances and additional packages must be subjected to
appropriate processing for reuse of the information contained
in these materials.
Do not dispose of electrical equipment in domestic waste!
Under the EU Directive 2012/19/EG on scrapped electrical and
electronic equipment and promoting law and national
electrical machines, which can be used more, must be collected
separately and be subjected to appropriate processing for
recovery of the information contained in these secondary
materials.
Summary of Contents for Pro RDP-WP44
Page 31: ...31 RDP WP44 exploded view ...
Page 32: ...32 www raider bg PARTS LIST RDP WP44 ...
Page 47: ...47 ...
Page 49: ...49 ...
Page 51: ...51 ...