14
6.2.5 Reassembly
Once wiring is completed, ensure that the mating surfaces
of both the cover and body are well covered with a
suitable anti-seize compound. Carefully lower the cover
assembly back onto the base, avoiding damage to the
mating surfaces, ensuring the O-ring is correctly seated in
its groove during reassembly. Replace the four M6 screws
into the holes in the cover assembly and tighten evenly.
Ensure the required gap (0.2mm maximum) is maintained
between the cover and the base.
6.2.6 External Grounding
If external or redundant grounding is required, a lug is
located on each light and the horn. There are also two
points on the exterior of the RAEPoint. Screw the ground
wire’s connector onto the lug and run it to the appropriate
grounding location.
7
Powering And Programming
Refer to the RAEPoint User’s Guide for information on
how to power, test, and program the RAEPoint. The horn
and lights are prewired, so all operations are controlled by
the RAEPoint.
Ground
Lug
Ground wire