11 

6.2.2 Opening The Horn 

You  must  remove  the cover  assembly  from  the front  of 
the  horn  in  order to connect  wires  to the  terminal  block. 
 
Unscrew  the four  M6 screws  (5.0mm  hex  key)  holding 
the  cover assembly  to the  base. Keep these  screws in  a 
safe,  accessible  place;  they  are not retained  in  the  cover. 

 

 

Before  lifting  the cover,  gently  twist  the  cover assembly 
clockwise  and then  counterclockwise  to break the seal. 
 
Continue to gently  twist the cover clockwise and counter-
clockwise while  gently  lifting  the cover assembly away from 
the base of the enclosure to gain  access to the interior. 
 

 

 

Note: 

The  cover  assembly  is  connected  to the  cover by a 

nylon  restraining  strap. 

Summary of Contents for RAEPoint

Page 1: ......

Page 2: ...chnical Service Department Before returning the instrument for service or repair obtain a Returned Material Authorization RMA number for proper tracking of your equipment This number needs to be on al...

Page 3: ...DC Powered Wireless Alarm Bar Wiring 8 6 2 1 Complete RAEPoint DC Powered Wireless Alarm Bar Wiring Diagram 9 6 2 2 Opening The Horn 11 6 2 3 Connecting Power Wiring 12 6 2 4 Internal Grounding 13 6...

Page 4: ...Installation Guide is for wiring and installation of the DC Powered Alarm Bar only It must be used in conjunction with the RAEPoint User s Guide for safe calibration and operation The RAEPoint User s...

Page 5: ...f electric shock turn the power off before opening this instrument or performing service Never operate the instrument when the instrument is open Use and service this product only in an area known to...

Page 6: ...onfigured as a wireless host and communicate directly with detectors providing a localized alarm notification solution that does not require a controller The RAEPoint DC Powered Wireless Alarm Bar is...

Page 7: ...The Waste Electrical and Electronic Equipment WEEE directive 2002 96 EC is intended to promote recycling of electrical and electronic equipment and their components at end of life This symbol crossed...

Page 8: ...d Wireless Alarm Bar can be configured for large or small systems and the network can be expanded or units removed depending on the facility or facilities being monitored Simple configuration that use...

Page 9: ...int DC Powered Wireless Alarm Bar Mounting Make sure that there is approximately 12 30 cm of clearance on all sides of the RAEPoint DC Powered Wireless Alarm Bar so that the horn s sound is not attenu...

Page 10: ...oint DC Powered Wireless Alarm Bar on a wall or other flat surface and mark the six holes locations 2 Remove the RAEPoint DC Powered Wireless Alarm Bar 3 Drill the six holes 4 Hold the RAEPoint DC Pow...

Page 11: ...through a connector at the bottom of the unit Note Ensure that only the correct listed or certified cable glands not included are used and that the assembly is correctly grounded earthed All cable gl...

Page 12: ...Complete RAEPoint DC Powered Wireless Alarm Bar Wiring Diagram The diagram on the next page shows how the RAEPoint DC Powered Wireless Alarm Bar is wired Refer to the diagram on page 12 for power conn...

Page 13: ...10...

Page 14: ...ews in a safe accessible place they are not retained in the cover Before lifting the cover gently twist the cover assembly clockwise and then counterclockwise to break the seal Continue to gently twis...

Page 15: ...Note This diagram only shows the connection points for external power and ground For clarity other wires for the RAEPoint DC Powered Wireless Alarm Bar are not shown Refer to the schematic drawing on...

Page 16: ...13 6 2 4 Internal Grounding If internal grounding is required connect the ground wire s connector to the location shown in the wiring diagram and tighten it down using the nut and washer...

Page 17: ...hten evenly Ensure the required gap 0 2mm maximum is maintained between the cover and the base 6 2 6 External Grounding If external or redundant grounding is required a lug is located on each light an...

Page 18: ...ow Alarm Bar Input Voltage 24 VDC Peak Current Consumption 1 5A 24 VDC IP Rating IP 65 Back Plate Material 316 stainless steel Dimensions 27 11 64 690 mm x 9 229 mm x 9 5 241 mm Weight 31 lbs 14 kg 5...

Page 19: ...del RM2400A Frequency range 2 400 to 2 4835GHz Modulation 802 15 4 DSSS BPSK RF power Tx 20dBm Data rate 250kbps RAEPoint Alarm Bar Hazardous Location Classification The RAEPoint DC Powered Wireless A...

Page 20: ...17 8 Replacement parts Refer to next page for part numbers and descriptions 5 4 1 3 2 SM87HXBA Lights DB1 Horn...

Page 21: ...NG DB1 HORN AC DC WIRELESS ALARM BAR 1 Ea F08 2104 000 PC BOARD DB1 HORN AC DC WIRE LESS ALARMBAR 1 Ea 4 F08 2114 000 YELLOWLENS AND LENS GUARD W O RING SM87HXBA DC WIRELESS ALARM BAR 1 Ea 4 F08 2115...

Page 22: ...61 Email tech raesystems com 10 RAE Systems Contacts RAE Systems by Honeywell World Headquarters 3775 N First St San Jose CA 95134 1708 USA Phone 1 408 952 8200 Fax 1 408 952 8480 E mail customerserv...

Page 23: ...4 78 46 16 65 Fax 33 4 78 46 25 98 Phone 33 4 78 46 16 65 Fax 33 4 78 46 25 98 Email info france raeeurope com Web www raesystems fr RAE BeNeLux BV Rijndal 20 2904 DC Capelle a d Ijssel Netherlands P...

Page 24: ...ystems com RAE Systems Japan Marunouchi Nakadori Bldg 6F 617 B 2 3 Marunouchi 2 Chome Chiyoda ku Tokyo 100 0005 Japan Phone 81 3 6269 9646 Fax 81 3 6269 9647 Email jpsales raesystems com RAE Systems K...

Page 25: ......

Reviews: