889-1600-04
Model P-1400 Operations Manual Rev Apr 2020 Page
9
of 33
When operating in Parallel Synch mode, if the master unit fails, all of the Vital Outputs of every detector
configured to operate in Synch mode will be deactivated. If one or more of the detectors connected to the master
unit Fails, only those Vital Outputs of the detector(s) that has (have) failed will be deactivated.
When operating in either Series or Parallel mode,
FSY
will be displayed on the LCD screen of the detector(s)
associated with the failure. This display state will continue until the problem is corrected and the detectors are
powered down and repowered, reset, or until the Synch function is turned off.
In either mode of operation, the Synch feature will continue to function if one or more detectors has (have) been
disabled.
3.4
TABLE: SENSITIVITY, -
∆
L/L, AND RESPONSE TIME
Sensitivity
-
ΔL/L
Response Time (milliseconds)
One
Detector
Two Detectors
Three Detectors
Four Detectors
Series
Synch
Parallel
Synch
Series
Synch
Parallel
Synch
Series
Synch
Parallel
Synch
OFF
-------
-------
-------
-------
-------
-------
-------
-------
1
5.12 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
2
2.56 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
3
1.28 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
4
0.64 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
5
0.32 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
6
0.16 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
7
0.08 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
8
0.04 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
9
0.02 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
10
0.01 %
121 ±25
268 ±52
278 ±58
400 ±80
278 ±58
530 ±110
278 ±58
CALL
-------
-------
-------
-------
-------
-------
-------
-------
3.5
TABLE: DEFAULT SETTINGS
Channel & Detector Settings
Function
Channel 1
Channel 2
Channel 3
Channel 4
Frequency
2
4
6
8
Sensitivity
6
6
6
6
Option 1 - Loop Inductance Display
OFF
OFF
OFF
OFF
Option 2 - Loop Inductance -
ΔL/L (%) Display
OFF
OFF
OFF
OFF
Option 3 - Noise Filter
3.00
3.00
3.00
3.00
Option 4 - Detection Zone Tracking
4.02
4.02
4.02
4.02
Option 5 - Sensitivity Boost
5.00
5.00
5.00
5.00
Option 6 - Audible Detect Signal
OFF
OFF
OFF
OFF
Loop Check Feature
005
005
005
005
Detector ID Setting
255
Option 7 - Synch Feature
7.00
Option 10- Inverted Vital Output
OFF
Vital Output Settings
Function
Setting
Primary Vital Output Delay Time
00.0
Primary Vital Output Extension Time
00.0
Primary Vital Output Mapping
00
Auxiliary Vital Output Mapping
000