User Interfaces
SFC6400A/SFC1450A Synthesized Frequency Upconverter
4-2
TM106 – Rev. 1.1
4.1.1 Monitoring Ports
Refer to Section 5.12.
4.1.2 LCD Display
The front panel display is a 2 line by 16-character LCD display. The display is lighted and the
brightness can be set to increase when the front panel is currently in use. The LCD display
automatically dims after a period of inactivity. The display has two distinct fields showing current
information. The upper field shows the current parameter being monitored, such as 'FREQUENCY
(GHz)' or 'CHNL GAIN (dB)'. The lower field shows the current value of that parameter. The LCD
display is a single entry window into the large matrix of parameters that can be monitored and set
from the front panel.
4.1.3 Cursor Control Arrows
Table 4-2. Cursor Control Arrow Keys
Key
Function
Left/Right
Arrow Keys
(
→
), (
←
)
The Left/Right Arrow Keys are used to move through the Menu structure. The
Left/Right Arrow Keys are also used to move the cursor to a specific digit in a
number field. No changes in the values or status can be executed from the
left/right cursor movement.
Up/Down
Arrow Keys
(
↑
), (
↓
)
The Down Arrow Key is used to move from a Menu screen to the selections or
submenus beneath that Menu. The Up Arrow does the reverse, moving from a
submenu or selection to a higher-level Menu.
The Up/Down Arrow Keys are also used to change the value of some
parameters. Some Menu items, such as SYSTEM<CONTROL MODE, contain
a list of possible settings. The Arrow Keys are used to scroll through the list
until the desired setting is displayed. Similarly, these keys toggle the ± sign of
any signed parameters. <ENTER> is then used to execute the selection.
For numerical parameters, such as CONVERTER<FREQUENCY(GHz), the
Arrow Keys can be used to scroll through the possible values of each particular
digit. The Left/Right Keys are used to move the cursor to the desired digit. To
execute a change, <ENTER> must be pressed.
4.1.3 Front Panel Keypad
The front panel keypad consists of two areas: a 10-key numeric entry with 2 additional keys for the
‘Enter’ and ‘Clear’ function. The second area is a set of ‘Arrow’ or ‘Cursor’ keys (
↑
), (
↓
), (
→
), (
←
),
used to navigate the parameter currently being monitored or controlled. Table 4-3 describes the key
functions available at the front panel.
Table 4-3. Front Panel Keypad
Key
Function
0 to 9
The Number Keys are used to change numeric values in the value field of the
LCD display.
Summary of Contents for SFC6400A
Page 2: ......
Page 14: ...Introduction SFC6400A SFC1450A Synthesized Frequency Upconverter 1 2 TM106 Rev 1 1 ...
Page 41: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 18 TM106 Rev 1 1 ...
Page 61: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 38 TM106 Rev 1 1 ...
Page 64: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 41 ...
Page 67: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 44 TM106 Rev 1 1 ...
Page 82: ...Rear Panel Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 5 10 TM106 Rev 1 1 ...
Page 96: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 6 TM106 Rev 1 1 ...
Page 106: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 16 TM106 Rev 1 1 ...
Page 117: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix A TM106 Rev 1 1 A 27 ...
Page 148: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix C TM106 Rev 1 1 C 19 END ...
Page 149: ...Appendix C SFC6400A SFC1450A Synthesized Frequency Upconverter C 20 TM106 Rev 1 1 ...
Page 156: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Glossary TM106 Rev 1 1 G 7 ...