SFC6400A/SFC1450A Synthesized Frequency Upconverter
Appendix C
TM106 – Rev. 1.1
C-7
}
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Selects MANUAL or AUTOMATIC backup modes.
Manual: A Prime Converter can be backed up through manual control only.
Auto-Nonrevertive: A Prime Converter will be backed up if it fails.
It will remain backed up until it is manually unbacked.
Auto-Revertive: A Prime Converter will be backed up if it fails.
If a second Converter of a higher priority (see 7. below) fails, the
Switch will unback the first and backup the second Converter. Also,
if the first Converter recovers after it has been backed up (i.e., no
longer has a fault), the Switch will unback it and place it online again."
::= { radConverterSwitchNVStatus 1 }
radConverterSwitchLearn OBJECT-TYPE
SYNTAX
PrimeControlType
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Learn Prime converter or learn All. Causes the Backup unit to 'Learn'
all the settings of the selected Primes. The Backup can only backup a
Prime that it has learned."
::= { radConverterSwitchNVStatus 2 }
radConverterSwitchBackupTest OBJECT-TYPE
SYNTAX
PrimeControlType
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Checks if Prime can be backed up."
::= { radConverterSwitchNVStatus 3 }
radConverterSwitchForceBackup OBJECT-TYPE
SYNTAX
INTEGER (0..8)
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Force a manual backup (select 1..8), or unback of a Prime (select 0).
When in Manual Backup Mode, this selection will force the selected Prime
to be backed up. Unback will release any Prime that is currently backed
up."
::= { radConverterSwitchNVStatus 4 }
radConverterSwitchPriority OBJECT-TYPE
SYNTAX
INTEGER (0..8)
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"Prime converter priority. Sets the switching priority of a Prime unit.
If more than one unit fails at the same time, the higher priority unit
will be backed up. Also, if one unit is currently backed up and a second
unit with a higher priority fails, the first unit w ill be unbacked and
the second unit will be backed up (but only if Backup Mode is
Auto-Revertive, see 1. above). The priority is set as follows.
0 = No priority (the Switch will ignore the Downconverter).
1 = Highest priority.
8 = Lowest priority."
::= { radConverterSwitchNVStatus 5 }
radConverterSwitchCompensationControl OBJECT-TYPE
Summary of Contents for SFC6400A
Page 2: ......
Page 14: ...Introduction SFC6400A SFC1450A Synthesized Frequency Upconverter 1 2 TM106 Rev 1 1 ...
Page 41: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 18 TM106 Rev 1 1 ...
Page 61: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 38 TM106 Rev 1 1 ...
Page 64: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 41 ...
Page 67: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 44 TM106 Rev 1 1 ...
Page 82: ...Rear Panel Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 5 10 TM106 Rev 1 1 ...
Page 96: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 6 TM106 Rev 1 1 ...
Page 106: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 16 TM106 Rev 1 1 ...
Page 117: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix A TM106 Rev 1 1 A 27 ...
Page 148: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix C TM106 Rev 1 1 C 19 END ...
Page 149: ...Appendix C SFC6400A SFC1450A Synthesized Frequency Upconverter C 20 TM106 Rev 1 1 ...
Page 156: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Glossary TM106 Rev 1 1 G 7 ...