1.  GENERAL INFORMATION

 

Antistatic ionizer is a device that removes excess of ions, both positive (cations) and 

negative (anions), from the sample, weighing device's components and the environment. 
Ionization is an operation aiming to neutralize electric charge of air molecules in order to 
restore quasi-balance of positive and negative ions. 

Imbalance of cations and anions in the air causes unwanted electric interaction (attraction 

and repulsion) between objects located close one to another. This process is even more 
intense in case of non-conductive materials (plastic, glass). When it comes to the weighing 
device, its operation is affected by the said interactions due to the fact that some of the 
device components are made of the said non-conductive materials. 

Affected operation as a results gives greater repeatability error, often also greater error of 

indication. 

2. TECHNICAL SPECIFICATIONS

'Sample - ions source' distance 

about 5 ÷ 50 cm 

Ions source 

stainless steel 

Net weight 

1.3 kg 

Ambient conditions: 
Temperature 
Humidity 

0 ÷ 40 ºC 
10 ÷ 80% 

Power supply 

15V DC / 2 W 

Summary of Contents for DJ-04

Page 1: ...Antistatic Ionizer DJ 04 Ionizer DJ 05 Ionizer IMMU 48 04 11 18 EN USER MANUAL www radwag com ...

Page 2: ...2 NOVEMBER 2018 ...

Page 3: ...TIONS 4 3 BASIC SAFETY PRECAUTIONS 5 4 MECHANICAL DESIGN OF DJ 04 and DJ 05 IONIZERS 7 5 UNPACKING 7 5 1 Unpacking 7 6 START UP 7 6 1 Operation 7 7 MAINTENANCE SERVICE RECYCLING 8 7 1 Maintenance 8 7 2 Service 8 7 3 Recycling 8 8 DECLARATION OF CONFORMITY 9 ...

Page 4: ... and repulsion between objects located close one to another This process is even more intense in case of non conductive materials plastic glass When it comes to the weighing device its operation is affected by the said interactions due to the fact that some of the device components are made of the said non conductive materials Affected operation as a results gives greater repeatability error often...

Page 5: ...izer s operation ozone is produced the workroom where the ionizer is operated must be equipped with a valid air conditioning system If the ionizer had been stored in a place where the temperature is much lower than the temperature of the workroom prior running the ionizer it is necessary to let its temperature stabilize leave the ionizer in the workroom for about 2 hours Otherwise humidity condens...

Page 6: ...be compatible with the mains rated voltage The power cord can be connected only to a socket with a ground contact The ionizer when not operated must be disconnected from the mains Any repairs to be done must be carried out by service authorized by RADWAG CAUTION It is forbidden to connect ionizer that is broken to the mains this may result with either electrocution or fire It is not allowed to use...

Page 7: ...refully remove the antistatic ionizer from the box and place it at its workstation 6 START UP The ionizer must be connected to the mains by means of power supply that comes standard with it Ionizer activation is signalled with diode placed on the housing when the ionizer is on the diode emits light 6 1 Operation Ionizer operates with positive and negative polarization in turns This enables effecti...

Page 8: ...cloth soaked with alcohol based substance 7 2 Service Only authorized RADWAG service points are allowed to disassembly repair and modify the ionizer It is recommended to subject the ionizer to technical inspection after 500 hours of operation replace ions source after 10 000 hours of operation 7 3 Recycling The device and the packaging must be recycled in accordance with valid state regulations Ma...

Page 9: ...9 8 DECLARATION OF CONFORMITY ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Reviews: