Performing the MCU Initial Configuration | 42
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Step 4
Select the Advanced IP (Dual-NIC) Configuration check box to expand that section of the page.
Figure 5-12
Dual-NIC configuration for management and media subnets
Step 5
Under Management Interface, enter the IP information for the management subnet:
a.
Enter the MCU’s IP address on the management subnet in the Primary IP address field.
b.
Enter the IP address of the management subnet’s router in the Router IP field.
Note:
The router IP address on this subnet must be distinct from the router on the media subnet.
If both cables are connected to the same router, you must use the MCU’s VLAN
functionality to send both media and management data to the same router. It will then
route the media and management data to different virtual subnets (or VLANs). For more
information on VLAN functionality, see the online help.
Step 6
Enter the IP information for the media and signaling subnet in the Media and Signaling Interface
section.
Step 7
Select Apply at the bottom of the page.
Step 8
The system restarts, terminating any live conferences. Select Yes to restart.
Step 9
Connect the cable for the media and signaling subnet to the right-hand ethernet port.
Note:
To access the management interface from an additional subnet to the one mentioned
above, select the More button at the bottom of the expanded section (
Figure 5-12 on
page 42
), to open the Additional Management Networks section. Enter the IP address of
the additional subnet’s router.