Performing the MCU Initial Configuration | 48
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Configuring the UDP Port for the Gatekeeper on the SCOPIA Elite MCU
The SCOPIA Elite MCU 5000 Series has designated port 1719 for gatekeeper use. You can configure
a different port to enable communication with the gatekeeper (for example, if port 1719 is busy).
Port 1719 is also used for RAS (to configure the UDP port for RAS, see
“Configuring the UDP Port
for RAS on the SCOPIA Elite MCU” on page 47
).
Note:
If you close port 1719, you must configure another port for both the gatekeeper and RAS. If you
configure a different port for the gatekeeper, you do not need to configure a different port for RAS.
Procedure
Step 1
Navigate to the MCU H.323 Protocol section by selecting Configuration > Protocols.
Step 2
Locate the Enable H.323 protocol section (see
Figure 5-17 on page 48
).
Figure 5-17
H.323 Protocol section of the Protocols tab
Step 3
Enter the port value in the Gatekeeper port field.
Step 4
Select Apply.
Configuring the TCP Port Q.931 on the SCOPIA Elite MCU
The SCOPIA Elite MCU 5000 Series has designated port 1720 for Q.931. You can configure a
different port to use Q.931 (for example, if port 1720 is busy). Q.931 is a telephony protocol used
for establishing and terminating the connections in H.323 calls.
Procedure
Step 1
Navigate to the MCU Advanced Commands section by doing the following:
a.
Select the
icon.
b.
Select Advanced parameters.
c.
Locate the H323 SIG port number in the Name column (see
Figure 5-18 on page 49
).