10. INSPECTION ITEMS AFTER INSTALLATION
11. ATTENTION
Due to thermal expansion and contraction, the heater will make noise when turning on and
off. The is a normal phenomenon and will not affect unit performance.
12. STARTING HEATER FOR THE FIRST TIME
1.
Do not turn on power before finishing all installation work.
2.
Make sure all wired connections are correct and firm.
3.
All objects must be removed from heater vicinity.
4.
Power-up heater and observe working status.
13. SAFETY PRECAUTIONS
1.
Do not use the same power outlet together with other appliances. Doing so may cause
current overload.
2.
Stop power supply immediately if heater fails or if wires are broken. Users should not
repair heaters themselves. Contact authorized servicer if heater fails.
3.
The radiant heater should not be placed directly above the power outlet.
4.
The radiant heater shouldn't be installed lower than 1.8 meters (6 feet) from the ceiling.
5.
The heater's surface cannot be covered.
6.
Do not hang objects from the heater.
7.
Distance from back of heater to ceiling/roof should not be closer than 150mm (3
inches). Distance from front of the heater and any object should not be within 1000mm
(3 feet). Distance from a side of the heater and any object should not be within 200mm
(7 inches).
8.
For cleaning, turn the unit off and wait for a minimum of 1 hour. Then use a damp cloth
to wipe exterior of the unit. Never use any cleaning products/chemicals on the heater
itself. DO NOT FLUSH OR SPRAY UNIT WITH WATER.
9.
Do not install or operate heater in areas with flammable or explosive objects or in areas
where users are susceptible to electric shock (wet areas).
10.
Do not insert any metal or foreign objects inside of heater.
Items to be checked
Improper installation
Is the unit stable?
The equipment may fall off or shake
Is heat insulation adequate?
May damage objects close to unit
Is power voltage the same as voltage shown on product nameplate?
Equipment failure
Is the wired connection correct?
Equipment failure
Is grounded electrical connection safe?
Risk of electrical leakage
Does wiring conform to standards?
Equipment failure or circuit