If any of the following symptoms appear while the tool is in use,
turn it off and disconnect it from the air supply immediately.
Failure to comply will lead to serious injury or loss of life.
Disconnect the tool from the air supply before making any adjustments.
Repairs must be performed by a qualified service technician only.
The following chart lists common issues and solutions. Please read it
carefully and follow all instructions carefully.
Air leakage at
the top of the
tool or in the
trigger area.
1. O-rings in the trigger
valve are damaged.
2.
The trigger valve
heads are damaged.
3.
Trigger valve stem,
seal, or O-rings are
damaged.
1.
Inspect and replace the O-ring.
2. Inspect and replace trigger valve
heads.
3. Inspect and replace the trigger
valve stem, seal, or O-ring
Air leakage
near the
bottom of the
tool.
1. The screws are loose.
2. The O-rings or the
bumper are worn or
damaged.
1. Tighten the screws.
2. Inspect and replace the O-rings
or the bumper.
Air leakage
between
the bottom
and the
cylinder
cap.
1. The screws are loose.
2. The O-rings or the
seals are worn or
damaged.
1. Tighten the screws.
2. Inspect and replace the O-rings
or the seals.