D6500 Computer Interface Manual
74-05313-000-G 10/16/97
Page 62
© 1988-1997 Radionics, Inc.
D6500 Computer Interface Installation Manual Supplement
This supplement is prepared for using the D6510A MPU and the D6541 Line Card in addition to the
D6500
Computer Interface Installation Manual.
Ademco Contact-ID
Receiver sends to computer:
D6500 Mode:
harrlsaaaa18QXYZGGCCCt
SIA Mode:
<LF><CRC>a<seq><rec><line>[#aaaa|18QXYZGGCCC]<CR>
Receiver sends to printer:
mm/ddshh:mmsCIDsLxxsACCTsaaaa
+++sACCTsaaaasNNNsEVENT=XYZsG=GGsC=CCC
CID: Contact-ID format
Lxx: Line number
NNN: If Q=1, print E/O for new Event or Opening. If Q=3, print R/C for Restore or Closing. If
Q=6, print OLD
Definition of automation output codes:
h:
Header
a:
Contact-ID protocol identifier
rr:
Receiver number
l:
Line Card number
s:
Space
aaaa: Account code
18: Format number for Contact-ID format
Q: Qualifier, 1=New event or opening
3=New restore or closing
6=Previous event
XYZ: Class code and event code (
see Appendix on page 5 and 6)
GG: Group number
CCC:
Zone codes or user ID
t:
Trailer
Ademco High Speed
Receiver sends to computer:
D6500 Mode:
h8rrlaaaasCCCCsCCCCsSt
SIA Mode:
<LF><CRC>8<seq><rec><line>[#aaaa|CCCCsCCCCsS]<CR>
Receiver sends to printer:
mm/ddshh:mmsHGHsLxxsACCTsaaaasCCCCCCCCsS
HGH: Ademco High Speed format
Lxx: Line number
Ademco High Speed continued on next page