Wiring Diagrams
Installation Guide CT100
6 Wire Heat/Cool
1. Connect the W wire to the W
terminal. This connects the heat.
2. Connect the Y wire to the Y
terminal. This connects to the
cooling compressor.
3. Disconnect the Rc and Rh
terminals by placing the
removing the Jumper Wire.
4. Connect the RH wire to the RH terminal and the RC wire to the RC
terminal. This connects power.
5. Connect the G wire to the G terminal. This connects the fan.
6. Connect the C wire to the C terminal. Your HVAC system is now
connected to the CT100.
7. Go to “Connect Your Wires” on page 9.
Multi-stage Heat & Multi-Stage Cool
The CT100 can handle up to 2
stages of HEAT and 2 stages of
COOL.
1. Connect the W and W2 wires to
the W and W2 terminals. This
connects the stages of HEAT.
2. Connect the Y and Y2 wires to
the Y and Y2 terminals. This
connects the stages of COOL.
3. Connect the RH or R wire to the RH terminal. This connects the
power.
4. Connect the G wire to the G terminal. This connects the fan.
5. Connect the C wire to the C terminal. Your HVAC system is now
connected to the CT100.
6. Go to “Connect Your Wires” on page 9.
POWER
HVAC SYSTEM
THERMOSTAT TERMINALS
C B O W
Y Y
2
R
H
RC G A
W
2
W
G
Y R
H
R
C
C
*R
C
and R
H
disconnected
POWER
HVAC SYSTEM
THERMOSTAT TERMINALS
C B O W
Y Y
2
R
H
RC G A
W
2
W
G
Y Y
2
R
C
W
2
20