CT100 Operation Guide
Customization
Set Filter Reminder
1. From the Menu screen, touch Filter.
2. Touch the Days counter to set a value between 0 and 999 days.
Diff erential
Used for multiple stage systems only. Not available on-screen for single stage systems.
The Diff erential is the number of degrees between the room
temperature and the target temperature at which the 2nd stage
will engage to bring the room temperature back to the target. The
default is 2°F. The programmable range is 2°F to 6°F (1°- 3°C).
To Change the Diff erential
1. From the Menu screen, touch DIFF.
2. Use the
or
arrows to set the Diff erential value. 2°F is
standard for very cold climates, and 4°F for warm climates.
3. Touch
to return to the Menu screen.
Mate
This icon indicates that the CT100 is not connected to a Z-Wave
network. For instructions on connecting, see page 30.
Calibrate
Your thermostat was accurately calibrated at the factory to ±1° F of
actual ambient temperature. However, you can change the display
temperature to match that of a previous thermostat, or to match
another thermostat already in your home. The range of change is
from -6°F to +6°F (-3°C to +3°C).
To change your Thermostat Calibration:
1. From the Menu screen, touch Calibrate.
2. Use the Temperature Adjust arrows to adjust the displayed
temperature up or down, as desired in 0.5° (F or C) increments.
The temperature value in the lower left corner of the screen
adjustments to show the changed temperature value. The
central display shows the modifi ed temperature reading that will
be displayed on the Home screen and used as the new room
temperature.
3. Touch
to return to the Menu screen.
Menu Screen Functions Cont.
CT100 Operation Guide
Customization
Recovery
The Recovery function determines whether your HVAC system will
attempt to meet the programmed target temperature quickly.
Economy Recovery (Slower)
Fast Recovery
Touch Recovery icons to toggle between settings.
HVAC Setup
When the unit mode is Off (see page 12
for details), touch HVAC
Setup to enter the HVAC settings screen. For details on using this
screen, see the CT100 Installation Guide.
Lock
The Lock feature prevents thermostat changes via the touchscreen.
Lock feature does not restrict Z-Wave access. Unlock allows all
changes; Partial lock allows temporary temperature adjustments;
Full lock prevents all changes.. The CT100 has 3 lock modes:
Unlock
Partial Lock
Full Lock
Partial Lock
• From the Menu screen, touch Unlock for 5 seconds. The Lock
icon changes to show Partial Lock. In this mode, you can only
temporarily override the CT100 target temperature with the
Temperature Adjust arrows.
Full Lock
• From the Menu screen, touch the Partial Lock for 5 seconds
to show the Full Lock icon. Once locked, you cannot make any
changes; the CT100 only responds to touching
and Menu.
Unlock
• If in Partial Lock, touch and hold icon for 5 seconds to switch to
Full Lock.
• If in Full Lock, touch and hold icon for another 5 seconds. Each 5
second touch and hold must be separate.
NOTE: Unlocking has to go this direction:
Unlock > Partial Lock > Full Lock > Unlock
• Touch
to return to the Manual screen.
Menu Screen Functions Cont.
41