104
105
Detailed Menu Reference
TGRP Menu
The TGRP menu is used when creating new Trunking Talkgroup
objects, or editing existing Trunking Talkgroup objects.
TGRP
Parameter
Options
Description
Scan Lists
On or Off for
Scan Lists 1-22
Sets membership in Scan Lists. Use
keys
to scroll through Scan Lists. Use
SEL
key to
toggle Scan List membership. A “
*
” next
to the Scan List number indicates that the
object is mapped to that Scan List.
TSYS
New or previously
stored trunking
system object
(TSYS)
To enter a new trunking system, use the
keys to scroll through the stored systems
until NEW appears, then press
SEL
to enter
the parameters for the new TSYS. To use a
trunking system that you have previously
entered, use the
keys to scroll to the
desired system.
ID
Decimal, hex or
AFS, depending
on TSYS type
The digital address of the talkgroup or indi-
vidual radio ID on the trunked radio system.
Type
Group or Private
Use
Group
for talkgroup ID,
Private
for
individual radio ID.
Tag
Alpha-numeric
text
The alphanumeric display name for the
TGRP. Use the standard text entry method
or QTXT to name the object.
L/Out
On or Off
Permanent lockout for the TGRP. Also ac-
cessed by pressing
FUNC L/OUT
while the
scanner is stopped on the TGRP object.
Priority
On or Off
Turns Priority Mode on or off for the TGRP
object.
LED Mode
Solid or Flash
Controls whether the Alert LED flashes
or remains on solid when the Alert LED is
used.
LED Color
0-7
Sets LED color to
0-7
as defined in the
GLOB menu. By default,
0
=LED Off,
1
=Red,
2
=Yellow,
3
=Green,
4
=Cyan,
5
=Blue,
6
=Magenta,
7
=White.
TGRP
Parameter
Options
Description
Latch LED
On or Off
Normally the Alert LED is active only while
the object is receiving a transmission. When
Latch
is on, the Alert LED will remain lit
after the transmission is complete, unless
overridden by a subsequent object that is
also using the Alert LED.
Backlight
On, Off or Flash
Controls whether the backlight should be
on, off or flashing while the object is active.
Alarm
None, Chirp,
Hi-Lo, Alert, Ring,
2-Chirp, Fast Hi-
Lo, DTMF#
Sets the Audible Alarm for the TGRP
object. When an Audible Alarm is selected,
the selected alarm will play at the begin-
ning of each transmission on the TGRP
object, or anytime the scanner stops for
activity on the TGRP object while scanning.
Fav
Yes or No
When On, the TGRP object is a member of
the Favorites Scan List.
Skywarn
Yes or No
When On, the CONV object is a member of
the Skywarn Scan List.
EXPERT BELOW
Delay
On or Off
Controls whether a Delay is used to wait
for reply traffic after a transmission on the
TGRP.
Delay Time
1-250 x 100 ms
Sets the amount of time (in 100 millisecond
intervals) for the wait for reply delay if Delay
is On, e.g., 20=2 seconds.
AudioBoost
On or Off
Applies a 6 dB boost to audio levels when
the object is active.
Hit Count
Numeric value
Increments each time a transmission is
received on the TGRP object. Global “Hit
Counts” must be set to ON. Press the
Dflt
softkey to reset to 0.
Summary of Contents for PRO-652