SPECIFICATIONS

Line Voltage .........................................................................................................................................125V

Line Current ...........................................................................................................................................15A

Frequency ...........................................................................................................................................60Hz

Operating Temperature ......................................................................................... 32 to 122

°

F (0 to 50

°

C)

Operating Humidity .............................................................................................. 0 – 75% non-condensing

UL Approvals ....................................................................................................................UL1449, UL1363

Number of AC Outlets ............................................................................................................................... 6

Cord Length/Plug Type ................................................................................................. 7ft, right angle plug

Circuit Breaker .......................................................................................................................................15A

Housing Material .................................................................................... Metal Cover plus Plastic Housing

PROTECTED WHEN LIT Indicator ......................................... Lights green when the AC line is protected

Power On Indicator .............................................................. Lights green when the AC power is turned on

Noise Frequency Range .............................................................................................. 100 kHz – 100 MHz

Noise Attenuation Level ............................................................................................................ Up to 20dB

Maximum Surge Voltage .................................................................................................................6,000 V

Composite Maximum Surge Current .......................................................................120 VAC Line: 42,500A

Phone Line ............................................................................................................................................. n/a

Total Maximum Surge Current ........................................................................................................42,500A

Composite Maximum Energy Dissipation..................................................................... 120 VAC Line, 788J

Total Maximum Energy Dissipation ..................................................................................................... 788J

Modes of Protection ..................................................... Three (Hot-Neutral, Hot-Ground, Neutral-Ground)

Clamping Time ................................................................................................................... <1 nanosecond

Clamping Voltage ................................................................................................................................400V

Specifications are typical; individual units might vary. Specifications are subject to change and
improvement without notice.

Summary of Contents for 61-2404

Page 1: ...ertinent information o Warning Important Caution Ô Note CAUTION This product is intended for indoor use only This surge protector is not a lightning arrestor and might not protect against lightning induced voltage surges Be sure the total wattage of all connected devices does not exceed 1 875 watts Use the surge protector only with a three prong standard AC plug The surge protector cannot provide ...

Page 2: ...ly strong surge the built in protection absorbs the surge to protect your equipment If the surge is strong enough it diminishes the protection circuitry s ability and the surge protector sounds an alarm If the PROTECTED WHEN LIT and ON indicators will not light replace the surge protector CARE Keep the surge protector dry if it gets wet wipe it dry immediately Use and store the surge protector onl...

Page 3: ...rotected Power On Indicator Lights green when the AC power is turned on Noise Frequency Range 100 kHz 100 MHz Noise Attenuation Level Up to 20dB Maximum Surge Voltage 6 000 V Composite Maximum Surge Current 120 VAC Line 42 500A Phone Line n a Total Maximum Surge Current 42 500A Composite Maximum Energy Dissipation 120 VAC Line 788J Total Maximum Energy Dissipation 788J Modes of Protection Three Ho...

Page 4: ...exclusions may not apply to you To make a claim for surge induced damage to Connected Equipment you must 1 Call RadioShack at 1 888 353 1560 for a return authorization number during the Warranty Period Under no circumstances will a claim for surge induced damage to Connected Equipment be accepted without a return authorization number 2 Have any surge induced damaged Connected Equipment repaired or...

Reviews: