83
Radijator Inženjering d.o.o, 36000 Kraljevo, Živojina Lazića
- Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
8.4 Mistakes during ignition and start of BIO
lux
14 Boiler Heating Stove.
All possible errors in the initial stage of operation, ie. during firing and can, even during the
operation, are shown in the display of the automation system. (Figure 16- ALARM error).
Errors and explanations are shown in the table.
All possible problems and stoppage in the operation of this device can be divided into two major
groups.
Group I. Stoppage during the first firing and the first firing after purchase of the boiler or
the first putting the boiler into operation during the day.
Group II. The delay that occurs when the boiler has already been in operation process ,
the display is there is a notification on the display ( Run Mode) , but after reaching the
set temperature and rest mode it loses the continuity of combustion .
Group I
The most common indication on the display related to this type of error is Er12.
During the first firing after the installation of the boiler, for the hydro installation there should
follow the instructions from the Section “Start of Operation of the Heating Boiler
-Stove."
Especially, pay attention to the flue outlet (diameter, number of arcs, sealing, ... ) as well as to
the chimney (diameter , height , insulation , sealing revision openings, dirt in chimney , etc.).
If, after the first attempt of firing there is no significant occurrence of flame and serious increase
in flue gas temperature,there is a signal on the display that the ignition heater is activated, and
yet the boiler goes into extinction phase (Extinguishing). In this case you should check out the
following causes: