REPLACING THE REACTOR CHAMBERS

In order for the VK 401 to remain functional the reactor chambers must be replaced every 8000 hrs. 
Your unit will indicate that a change is required, “-001” displayed on the LCD. 

1. Switch off, and unplug the unit.

2. Remove the 12 screws at the back of the unit.

5. Remove the 4 corner screws out of both the 
chamber mountings, being careful to ensure 
that the earth wire (yellow) closest to the switch-
board is detached and remains intact.

6. Remove the old reactor chambers and replace 
with the new chambers which are already linked 
together, then return the 4 screws to the corners 
of each chamber, ensuring that the earth wire is 
reconnected to the screw closest to the circuit 
board, and then connect the new reactor cable 
to the circuit board.

7. Close the unit carefully making sure that no 
wires are trapped or damaged, return the 12 
screws to the back of the unit.

8. Now switch your VK 401 back on, press and 
hold the down button for 14 seconds, to reset the 
warning timer. Now your VK 401 is ready for the 
next 8000 hours.

3. Place the unit on its back, and carefully 
     lift open the front of the unit.

       (make sure no wires are disconnected 
       when lifting the front cover)

4. Remove the black and white cable linked to 
     the reactor chambers. (marked J5 on the PCB)

earth wire

Summary of Contents for VIRUSKILLER VK 401

Page 1: ...USER GUIDE AND INSTRUCTIONS AIR STERILISER VK 401...

Page 2: ......

Page 3: ...a toy This appliance is NOT to be used by children or persons with reduced physical sensory or mental capabilities Children should be supervised at all times Never look directly at a burning ultra vi...

Page 4: ...IDE CARBON FILTERS 9 REPLACING THE HEPA FILTER 10 REPLACING THE REACTOR CHAMBERS 11 ERROR MESSAGES 12 TROUBLESHOOTING 13 CUSTOMER SERVICES 14 SPECIFICATIONS 14 Warning Indicates important safety instr...

Page 5: ...se seri ous injuries Do not sit stand or place heavy objects on the unit as this may result in injury and or damage to the unit Do not block the air inlet of the unit as this will reduce the air flow...

Page 6: ...icted or obstructed by large items such as furni ture electronic items or cur tains Use a dedicated power outlet Lightning or static electricity could affect the circuit and may cause a fire or damage...

Page 7: ...and Monitoring Changes the information displayed on the LED in the following order UV Lamp Time Current Temp Fan Speed Power button ON OFF To switch the unit ON Off You will hear a beep sound Fan Spe...

Page 8: ...l FAN 3 High Speed 3 Fan Speed Down Decreases the fan speed 4 Mode Changes the information displayed on the LED in the following order UV Lamp Time Current Temp Fan Speed 5 Timer Sets a working time f...

Page 9: ...mpletely before reinstalling You can now put the filters back into the case and place this back into your VK 401 Make sure that the carbon part of the filter is facing the back on the unit Close the f...

Page 10: ...lters back into the unit Make sure that the carbon part of the filter is facing the back on the unit Close the handle and the unit can be switched back on f Press and hold the up switch on the unit fo...

Page 11: ...lready linked together then return the 4 screws to the corners of each chamber ensuring that the earth wire is reconnected to the screw closest to the circuit board and then connect the new reactor ca...

Page 12: ...When you see this warning message it is time to replace the Reactor Cell This is an error message that refers to a malfunction of the UV lamps Turn the unit off and contact customer service This is an...

Page 13: ...not work properly The indoor air is heavily contaminated The room requires ventilation The pre filter is blocked Clean the pre filter The HEPA filter is blocked Replace the HEPA filter The room is to...

Page 14: ...ing use of products such as benzene or thinners incorrect power supply or output voltage breakdown or loss of part caused by unauthorized disassembling or modifications repair or replacement undertake...

Page 15: ......

Page 16: ...BL1 4BA Tel 44 0 1204 238823 E mail info radic8 com Manufacturer INBair Korea LTD 3 4F 72 Jomaru ro 411 Beon gil Bucheon si Gyeonggi do South Korea E mail inbair01 naver com www inbair com Made in Kor...

Reviews:

Related manuals for VIRUSKILLER VK 401