SERVICING AND MAINTENANCE INSTRUCTIONS
_
Parameter
3
setting:
HEATING TEMPERATURE SETTING
To modify the
Parameter value
:
a.
Put ON/OFF button
1
in
OFF
position (
);
b.
Push pad
6
and
4
simultaneously and keep them pressed
;
c.
Put ON/OFF button
1
in
ON
position
(
)
and wait until the display shows
-
;
P
0
d.
Release pad
6
and
4
;
e.
Keeping pad
5
pressed
,
press pad
6
and select parameter no.
;
3
f.
Release service pad
5
;
press and release service pad
5
;
g.
The display
will show the parameter value to be set or modified;
h.
Press pad
6
or
4
to modify (increase or decrease) the parameter value
STANDARD from 30 to 80°C
,
REDUCED from 25 to 40°C
;
0
0
i.
Press and release service pad
5
to confirm setting;
j.
The display will show parameter no.
;
k.
Position ON/OFF button
1
first in OFF position (
) and back to ON position (
);
3
Parameter “
4
” setting:
PUMP SETTING IN HEATING MODE
To modify the
Parameter value
:
a.
Put ON/OFF button
1
in
OFF
position (
);
b.
Push pad
6
and
4
simultaneously and keep them pressed
;
c.
Put ON/OFF button
1
in
ON
position
(
)
and wait until the display shows
-
;
P
0
d.
Release pad
6
and
4
;
e.
Keeping pad
5
pressed
,
press pad
6
and select parameter no.
;
4
f.
Release service pad
5
;
press and release service pad
5
;
g.
The display
will show the parameter value to be set or modified;
h.
Press pad
6
or
4
to modify (increase or decrease) the parameter value
STANDARD (pump overrun)
,
PERMANENT (pump ON all the time)
;
0
0
i.
Press and release service pad
5
to confirm setting;
j.
The display will show parameter no.
;
k.
Position ON/OFF button
1
first in OFF position (
) and back to ON position (
);
4
CONDENSING WALL-HUNG BOILER – TG05A062.A0505