MAINTENANCE INSTRUCTIONS
40
PARAMETER
P23
–
MODULATING
PUMP
MINIMUM
SPEED
( w/modulating pump and return temperature sensor
connected only)
This parameter is used to set the minimum modulating pump speed
during a heating mode request.
To enter the parameters menu, follow the previously described procedure
(
see paragraph
5.2 ‘Accessing the parameters menu’
- steps 1-4)
.
5.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify
the value of the parameter within the prescribed limits
(
displayed
in
percentage):
min = 50 %
max = 70 %
6.
Press mode selection button ‘
’ to confirm and to render the new
parameter operative
.
7.
To exit from the parameters menu, press simultaneously ‘
’ and ‘
’
buttons
.
PARAMETER
P24
–
MODULATING
PUMP
MAXIMUM
SPEED
(w/modulating pump and return temperature sensor connected
only)
This parameter is used to set the maximum modulating pump
speed during a heating mode request.
To enter the parameters menu, follow the previously described procedure
(
see paragraph
5.2 ‘Accessing the parameters menu’
- steps 1-4)
.
5.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify
the value of the parameter within the prescribed limits
(
displayed
in
percentage):
min = 70 %
max = 100 %
6.
Press mode selection button ‘
’ to confirm and to render the new
parameter operative
.
7.
To exit from the parameters menu, press simultaneously ‘
’ and ‘
’
buttons
.
PARAMETER
P25
–
∆
T
TIMING
T°
FLOW
/
T°
RETURN
(w/modulating pump and return temperature sensor connected
only)
This parameter is used to set the timing response of the
modulating pump.
To enter the parameters menu, follow the previously described procedure
(
see paragraph
5.2 ‘Accessing the parameters menu’
- steps 1-4)
.
5.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify
the value of the parameter within the prescribed limits
(
displayed
in
seconds):
min = 20
max = 100
6.
Press mode selection button ‘
’ to confirm and to render the new
parameter operative
.
7.
To exit from the parameters menu, press simultaneously ‘
’ and ‘
’
buttons
.
P23
P23
P24
P24
P25
P25
60
75
100
80
30
20
Summary of Contents for RK 25 /B