2. FIRST START-UP
SUPPOR
T
CENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P14
STARTING STEP ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN
SPEED DURING START-UP
THE VALUE IS PRE-SET BASED ON THE SET POWER
(SEE PARAMETER P00) AND ON THE GAS TYPE (SEE
PARAMETER P02).
SEE CHAPTER
‘
H
E
A
T
C A P A C I T Y
D I A G R A M
(KW) –
ELECTRIC FAN
F R E Q U E N C Y
(HZ)’
THE VALUE IS EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P15
ANTI-LEGIONELLA FUNCTION
(FOR STORAGE BOILERS ONLY)
THROUGH THIS PARAMETER YOU CAN ACTIVATE/
DEACTIVATE THE “ANTILEGIONELLA” HEAT
TREATMENT OF THE STORAGE TANK AND SET
THE DAYS AFTER THAT THIS FUNCTION CAN BE
AUTOMATICALLY ACTIVATED. THE DEFAULT VALUE
IS 7 DAYS. STARTING FROM THAT MOMENT THE
WATER TEMPERATURE INSIDE THE STORAGE
IS HEATED BEYOND 60 °C THUS GENERATING
A BURNING HAZARD. KEEP UNDER CONTROL
SUCH DOMESTICH HOT WATER TREATMENT (AND
INFORM THE USERS) TO AVOID UNFORSEEABLE
DAMAGES TO PERSONS, ANIMALS AND PROPERTY.
A THERMOSTATIC VALVE SHOULD BE INSTALLED AT
THE DOMESTIC HOT WATER OUTLET TO AVOID ANY
BURNS.
00 - 15
00 = DISABLED
01-15 = DAYS AFTER THAT THE FUNCTION IS
AUTOMATICALLY ACTIVATED