2.    MAINTENANCE

SUPPOR

T

 C

ENTRE

Technical parameters for boiler space heaters, boiler combination heaters and cogeneration 
space heaters

Model

R1KG 24

Condensing boiler

[yes/no]

yes

Low-temperature (**) boiler: 

[yes/no]

no

B11 boiler

[yes/no]

no

Cogeneration space heater

[yes/no]

no

If yes, equipped with a supplementary heater

[yes/no]

no

Combination heater

[yes/no]

no

Rated heat output Prated

kW

22,70

For  boiler  space  heaters  and  boiler  combination 
heaters: Useful heat output

At rated heat output and high-temperature regime (*) P

4

kW

22,70

At 30 % of rated heat output and low-temperature regime (**) 
P

1

kW

7,05

For cogeneration space heaters: Useful heat output

At  rated  heat  output  of  cogeneration  space  heater  with 
supplementary heater disabled P

Sup0

kW

-

At  rated  heat  output  of  cogeneration  space  heater  with 
supplementary heater enabled  P

Sup100 

kW

-

)RUFRJHQHUDWLRQVSDFHKHDWHUV(OHFWULFDOHႈFLHQF\

At  rated  heat  output  of  cogeneration  space  heater  with 

VXSSOHPHQWDU\KHDWHUGLVDEOHGȘ

el,Sup0 

%

-

At  rated  heat  output  of  cogeneration  space  heater  with 

VXSSOHPHQWDU\KHDWHUHQDEOHGȘ

el,Sup100

%

-

$X[LOLDU\HOHFWULFLW\FRQVXPSWLRQ

At full load elmax

kW

0,04

At part load elmin

kW

0,02

In standby mode PSB

kW

0,004

6HDVRQDOVSDFHKHDWLQJHQHUJ\HႈFLHQF\Ș

s

%

91

6HDVRQDOVSDFHKHDWLQJHQHUJ\HႈFLHQF\FODVV

A

For  boiler  space  heaters  and  boiler  combination  heaters: 

8VHIXOHႈFLHQF\
$WUDWHGKHDWRXWSXWDQGKLJKWHPSHUDWXUHUHJLPHȘ

4

%

87,1

At 30 % of rated heat output and low-temperature regime 

Ș

1

%

96,3

)RUFRJHQHUDWLRQVSDFHKHDWHUV8VHIXOHႈFLHQF\

At  rated  heat  output  of  cogeneration  space  heater  with 

VXSSOHPHQWDU\KHDWHUGLVDEOHGȘ

Sup0 

%

-

At  rated  heat  output  of  cogeneration  space  heater  with 

VXSSOHPHQWDU\KHDWHUHQDEOHGȘ

Sup100 

%

-

6XSSOHPHQWDU\KHDWHU

Rated heat output Psup 

kW

-

Type of energy input

-

Other items

Standby heat loss P

stby 

kW

0,1

Ignition burner power consumption P

ign

kW

0,0

Summary of Contents for R1KG 24

Page 1: ...R1KG 24 RAD ING Manuale 1806 1_SK 2 Installation Use and Maintenance Manual for model 0476 R1KG 24 Premix condensing system boiler only heating...

Page 2: ...3 GAS CONNECTION 18 1 1 14 ELECTRICAL CONNECTION 18 1 1 15 POWER SUPPLY 19 1 1 16 OPTIONAL ELECTRICAL CONNECTIONS 20 1 1 17 FUME EXHAUST FITTINGS 22 1 1 18 INSTALLATION MODES 23 1 1 19 TYPES OF FUME E...

Page 3: ...TRANSFORMATION 58 3 USER SECTION 59 3 1 USE 60 3 1 1 GENERAL USE WARNINGS 60 3 1 2 CONTROL PANEL 61 3 1 3 DISPLAY ICONS 62 3 1 4 INFO MENU DISPLAY DATA 63 3 1 5 START UP 64 3 1 6 OPERATING MODE 64 3...

Page 4: ...ferentiated by thickness and size in accordance with their hierarchy The images contain important parts described in the text marked with numbers or letters See chap chapter name this entry indicates...

Page 5: ...thout any obligation to third parties neither will the company be held responsible for any inaccuracies in this handbook deriving from printing or translation errors the material and intellectual owne...

Page 6: ......

Page 7: ...be performed only by qualified personnel having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water productio...

Page 8: ...performance The location must be properly vented through an air vent The air vent must be placed at floor level to prevent it from being obstructed protected by a grid that does not hamper the useful...

Page 9: ...electrical resistances kit see chapter ANTI FREEZE PROTECTION WARNING The manufacturer will not be held responsible for damages caused by incorrect installation not in conformity with the over mention...

Page 10: ...cking elements cardboard box woodencrate nails fasteners plasticbags expanded polystyrene etc must be kept out of the reach of children as they may be dangerous Therefore they should be dismantled sui...

Page 11: ...nuale 1806 1_SK 2 1 Dimensioni_R1KG_EN 1 INSTALLATION INSTALLER 1 1 5 OVERALL DIMENSIONS 1 1 6 JIG 380 325 150 255 845 450 655 50456055 240 765 A R G F A R G F R HEATING RETURN 3 4 G GAS 3 4 F COLD 1...

Page 12: ...ECHNICAL SPACES The appliance must be installed exclusively on a flat horizontal solid floor capable of supporting its weight In order to allow the access inside the boiler for maintenance operations...

Page 13: ...TALLER 1 1 8 CIRCULATOR PREVALENCE FLOW DIAGRAM Appliance Loss Wilo Yonos PARA MSL 12 6B 0 0 4 0 8 1 2 1 6 2 0 2 4 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 2 4 6 8 0 1 2 3 4 5 6 7 8 0 10 20 30 40 50 70 60 80 0...

Page 14: ...operations from any off axis positioning that may damage the tubes causing leaks malfunction or early wear WARNING In order to avoid any vibrations and noises do not use tubes with small diameters or...

Page 15: ...wering up the boiler fill the system as follows 1 slightly loosen the cap of the circulator jolly valve 1 fig 1 to release the air from the system 2 slightly loosen the cap of the jolly valve placed o...

Page 16: ...r which corresponds to the middle part of the green zone ZV fig 4 1 1 11 FILLING THE CONDENSATE COLLECTION SIPHON Before starting the boiler you have to fill the condensate collection siphon in order...

Page 17: ...heating flow water temperature reaches the 30 C and in presence of a return sensor until the heating return water temperature reaches the 20 C The system starts even if on the display appears OFF as l...

Page 18: ...te 1 1 14 ELECTRICAL CONNECTION DANGER The equipment is electrically safe only if it is properly connected to an efficient grounding system performed in compliance with the safety standards in force Y...

Page 19: ...boiler s front casing refer to chapter ACCESSING THE BOILER loosen the two screws and remove the plate A see fig 1 after removing the plate connect the electrical cables to terminal B see fig 1 the ye...

Page 20: ...e fig 1 For the external temperature Probe connect the two non polarized conductors to the Se Se contacts For the environment Thermostat or Remote control first remove the bridge on the Ta Ta contacts...

Page 21: ...e crankcase connect the items below to the electronic board see fig 1 After performing these operations remount the crankcase and the front casing TP CT BUS 0 10V GND BUS 11 10 9 8 7 12 13 14 15 16 17...

Page 22: ...to favour the reflux of the condensate towards the combustion chamber suitably realized to collect and drain acid condensate For all air suction ducts with regard to the air path you should provide an...

Page 23: ...ificated separately C83 Discharge in single or common fume exhaust duct and wall suction system C93 Discharge through an intubated conduct to a vertical terminal The technical compartment in which is...

Page 24: ...length a section equal to or greater then that of the connection of the device discharge tube have no shut off devices shutters for direct external discharge there must be no more than two changes in...

Page 25: ...combustion through co axial ducts the external one for air intake the plastic internal one for fumes discharge PLEASE SEE THE MAXIMUM DISCHARGE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximu...

Page 26: ...ing fuel gas and air suctioning for combustion through two separated ducts PLEASE SEE THE MAXIMUM DISCHARGE AND INTAKE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximum discharge and intake le...

Page 27: ...co axial ducts the external one for air intake the plastic internal one for fumes discharge PLEASE SEE THE MAXIMUM DISCHARGE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximum discharge length...

Page 28: ......

Page 29: ...s described below relative to first start up maintenance and replacement should be performed only by qualified personnel and authorized by RADIANT BRUCIATORI S p A 1 SUPPORT CENTRE SECTION 2 SUPPORT C...

Page 30: ...ke sure that the grounding system works properly make sure that the combustion air adduction and fumes and condensate discharge take place properly in compliance with the Local and National Laws and S...

Page 31: ...circulating pump automatic reset again further 3 minutes and switch off the power supply and switch it on again Open the gas tap Use the button to select the desired operation mode If the symbol is di...

Page 32: ...the screw 2 fig 2 of the Off Set adjuster To increase the CO2 value turn the screw clockwise and vice versa if you want to decrease it Once completed the adjustment tighten the protection screw A fig...

Page 33: ...ING THE PARAMETERS To access the parameters menu and adjust their values follow the procedure below 1 Press the button to select the OFF mode displayed using the symbol 2 Hold at the same time the key...

Page 34: ...T CENTRE 4 Use the keys and of the symbol S to change the value of the parameter 5 Press the key to confirm the action and wait for the display to stop blinking indication of the fact that the adjustm...

Page 35: ...LER MODEL SELECTION 0 10 0 13 KW 1 18 KW HEAT 24 KW DOMESTIC 2 25 KW 3 28 KW 4 34 KW 5 55 KW 6 100 KW 7 R1K 18_24 R2K 24 R2KA 24 IN ALL VERSIONS 8 R1K 25_28 R2K 28 R2KA 28 IN ALL VERSIONS 9 R1K 34 R2K...

Page 36: ...ET THE TIME DURING START UP PHASE NECESSARY FOR THE BOILER TO REACH THE MAXIMUM SET POWER ON THE HEATING SIDE 0 4 0 DISABLED 1 50 SECONDS SET BY DEFAULT 2 100 SECONDS 3 200 SECONDS 4 400 SECONDS P05 A...

Page 37: ...TO OPERATE IN DOMESTIC MODE THE VALUE IS PRE SET BASED ON THE SET POWER SEE PARAMETER P00 AND ON THE GAS TYPE SEE PARAMETER P02 45 VALUE SET FOR PARAMETER P11 THE VALUE IS EXPRESSED IN HERTZ 1HZ 30 RP...

Page 38: ...STMENT THROUGH THIS PARAMETER YOU CAN SET THE FAN SPEED DURING START UP THE VALUE IS PRE SET BASED ON THE SET POWER SEE PARAMETER P00 AND ON THE GAS TYPE SEE PARAMETER P02 VALUE SET FOR PARAMETER P10...

Page 39: ...5 C THE SYSTEM TYPE CAN BE SET FROM PARAMETER P03 0 30 SET BY DEFAULT AT 15 THE NUMBERING OF THE VALUE CORRESPONDS TO KD CURVES ON THE CHART SEE CHART BELOW P17 DISABLEMENT OF DOMESTIC HOT WATER LINE...

Page 40: ...E IS EXPRESSED IN C P21 MAXIMUM DOMESTIC SETPOINT THROUGH THIS PARAMETER YOU CAN SET THE USER ADJUSTABLE MAXIMUM DOMESTIC TEMPERATURE 45 75 THE VALUE IS EXPRESSED IN C P22 SET POINT T DELIVERY RETURN...

Page 41: ...UPPORT CENTRE PARAMETER DESCRIPTION RANGE FUNCTION P25 D H W STORAGE TANK TEMPERATURE SETPOINT FOR STORAGE BOILERS ONLY THROUGH THIS PARAMETER YOU CAN SET THE PRIORITY STARTING VALUE OF THE STORAGE TA...

Page 42: ...4_EN 2 FIRST START UP SUPPORT CENTRE 2 1 6 ELECTRIC FAN FREQUENCY HEAT CAPACITY DIAGRAM GAS TYPE MINIMUM FREQUENCY MAXIMUM FREQUENCY G20 Hz 45 188 G30 Hz 45 177 G31 Hz 45 190 G30 G20 G31 0 2 4 6 8 10...

Page 43: ...d proceed as indicated in section CO2 VALUE CHECK AND CALIBRATION remove and clean the burner from oxidation check the integrity and the position of the sealed chamber sealing gasket check the primary...

Page 44: ...4 Fumes temperature at nominal heat capacity C 80 26 Fumes temperature at minimum heat capacity C 65 7 CO2 at nominal heat capacity G20 9 3 9 1 CO2 at minimum heat capacity G20 9 8 8 CO2 at nominal h...

Page 45: ...x m 10 Max discharge length 80 125 Vert Co ax m 12 Max discharge length 50 50 Vert Split m 10 Max discharge length 60 60 Vert Split m 32 Max discharge length 80 80 Vert Split m 60 Max discharge length...

Page 46: ...h supplementary heater enabled PCHP100 Sup100 kW RU FRJHQHUDWLRQ VSDFH KHDWHUV OHFWULFDO H FLHQF At rated heat output of cogeneration space heater with VXSSOHPHQWDU KHDWHU GLVDEOHG el CHP100 Sup0 At r...

Page 47: ...KHDWLQJ HQHUJ H FLHQF wh Daily fuel consumption Qfuel kWh Annual fuel consumption AFC GJ Contact details Tel 39 0721 9079 1 fax 39 0721 9079299 e mail info radiant it http www radiant it Name and addr...

Page 48: ...ER UNIT 4 DETECTION ELECTRODE 5 RETURN PROBE 6 ELECTRIC FAN 7 CONDENSATE COLLECTION SIPHON 8 EXPANSION TANK 9 MODULATING PUMP 10 AIR RELIEF VALVE 11 HEATING PROBE 12 SAFETY THERMOSTAT 13 AIR SUCTION T...

Page 49: ...E 2 FUMES SAFETY THERMOFUSE 3 HEAT EXCHANGER 4 BURNER UNIT 5 ELECTRIC FAN 6 GAS VALVE 7 WATER PRESSURE SWITCH 8 SAFETY VALVE 3 bar 9 CONDENSATE COLLECTION SIPHON 10 CIRCULATOR 11 SYSTEM DRAINING TAP 1...

Page 50: ...NT THERMOSTAT AR ORANGE VG GAS VALVE SR HEATING PROBE L LINE GI YELLOW TRA START UP TRANSFORMER EV ELECTRIC FAN N NEUTRAL BI WHITE SRI RETURN SENSOR NE BLACK GR GREY ma ce ma ce ma ce ma gi bi gr EV c...

Page 51: ...er 1 fig 1 by pulling it vertically grab panel 2 fig 1 from the upper side and rotate it downwards To remove the panel completely first dismantle the electronic PCB front panel from the support bracke...

Page 52: ...in switch Follow the procedure described at chapter ACCESSING THE BOILER and rotate panel 2 fig 1 Unscrew the four fixing screws see A fig 2 remove the carter upwards see B fig 2 To access the termina...

Page 53: ...activate it turn off the main power supply switch wait for the boiler to cool down connect a flexible tube to the system emptying outlet and connect the other end of the tube to a suitable discharge...

Page 54: ...ESET E01 FLAME BLOCK NO FLAME LIGHT UP MANUAL RESET PRESS THE RESET KEY GAS MISSING CHECK THE ADDUCTION NETWORK MASS OR BROKEN START UP ELECTRODE REPLACE IT GAS VALVE BROKEN REPLACE IT SLOW LIGHT UP T...

Page 55: ...UFFICIENT WATER PRESSURE INSIDE THE SYSTEM LOWER THAN 0 3 BAR LOAD THE SYSTEM AUTOMATIC WATER PRESSURE SWITCH CABLE DISCONNECTED CHECK THE WIRING WATER PRESSURE SWITCH BROKEN REPLACE IT E05 HEATING PR...

Page 56: ...RD MICRO PROCESSOR IF THE MODULATION BOARD DOES NOT RESET THE ERROR AUTOMATICALLY REPLACE IT AUTOMATIC E22 P A R A M E T E R S PROGRAMMING REQUEST MICRO PROCESSOR MEMORY LOSS PARAMETERS REPROGRAMMING...

Page 57: ...CTIVATES AUTOMATICALLY WHEN THE HEATING PROBE DETECTS A TEMPERATURE OF 12 C THE BOILER OPERATES AT MINIMUM GAS PRESSURE WITH THE DIVERTER VALVE SET TO WINTER MODE IT DEACTIVATES WHEN THE HEATING FLOW...

Page 58: ...3 and apply pressure on the rear side of venturi C fig 3 replace the body venturi with the one suitable for the type of supply gas cod 30 00124 for methane cod 30 00170 for GPL and make sure the tooth...

Page 59: ...are addressed to all those who will use the machine The machine must be used and accessed only by qualified operators that fully read and understood the User section paying particular attention to th...

Page 60: ...due to incorrect use DANGER The boiler should not be used by persons including children with reduced physical sensory or mental capacities or without suitable knowledge or experience unless they are...

Page 61: ...S AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHIMNE...

Page 62: ...TEMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT 9 I...

Page 63: ...displayed data To exit display mode press the INFO key LIST OF DISPLAYED DATA INFO CODE ICON DESCRIPTION d0 DOMESTIC CIRCUIT PROBE TEMPERATURE d1 EXTERNAL PROBE TEMPERATURE d2 FAN SPEED d3 BOTTOM ARE...

Page 64: ...TEMPERATURE You can adjust the temperature using keys and of the heating circuit press key to decrease the temperature press key to increase the temperature The heating temperature adjustment field ra...

Page 65: ...IONAL NOTE ON ANTI FREEZE FUNCTION The boiler is protected against freezing thanks to the electronic board preparation with functions that start the burner and heat the concerned parts when their temp...

Page 66: ...essure reaches 1 2 bar which corresponds to the middle part of the green zone ZV fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressur...

Page 67: ...PPORT CENTRE E02 SAFETY THERMOSTAT 95 C CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CONTACT THE TECHNICAL SUPPORT CENTRE E04 WATER MISSING IN THE SYSTEM IF THE SYSTEM PRESSU...

Page 68: ...THE MAIN SWITCH AND THEN RESTORE IT AS SOON AS THE ERROR CODE DISAPPEARS THE BOILER WILL RESTART AUTOMATICALLY IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE E35 RESIDUAL FLAME PRESS THE R...

Page 69: ...ttive_solo risc_MIAH4_EN 3 USE USER 3 1 10 ACTIVE FUNCTIONS SIGNALLING CODES CODE FUNCTION INTERVENTION F08 H E A T I N G A N T I F R E E Z E FUNCTION ACTIVE WAIT UNTIL THE OPERATION IS COMPLETED F33...

Page 70: ...device using a wet cloth and come neutral soap WARNING DONOTuseabrasiveorpowderdetergents as they might damage the plastic cover and control elements 3 1 13 DISPOSAL The boiler and all its accessories...

Page 71: ......

Page 72: ...RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 39 0721 9079279 e mail info radiant Internet http www radiant it...

Reviews: