background image

25

R1C 24 /B - RAD - ING - Manuale - 2007.1_SK.3_MIAB3013_R7_VK42_B3

1 T

ip

o

lo

gia di s

c

ar
ico
_

V

_

EN

1. INSTALLATION  

INST

ALLER

KIT V - VERTICAL CO-AXIAL SYSTEM Ø60/100 
INTERNAL POLYPROPYLENE DUCT. 

It allows fumes discharge and air intake directly 
from roof.

Suitable only for condensing boilers.

It allows fuel gas discharge and air intake for 
combustion through co-axial ducts, the external 
one for air intake, the plastic internal one for 
fumes discharge.

PLEASE SEE THE MAXIMUM DISCHARGE LENGTH 
IN THE TABLE IN CHAPTER “TECHNICAL DATA”.

The maximum discharge length (or linear 
reference length) can be calculated summing the 
length of the linear tube and that equivalent to 
each additional curve with respect to the first.

Subsequent addition of a curve is similar to adding 
a linear length of tube according to the indications 
below:

curve Ø60/100 at 90° = 1 m

curve Ø60/100 at 45° = 0.6 m

Ø100

Ø 60

Summary of Contents for R1C 24/B

Page 1: ...R1C 24 B RAD ING Manuale 2007 1_SK 3_MIAB3013_R7_VK42_B3 Installation Use and Maintenance Manual for model 0476 R1C 24 B Premix condensing system boiler for remote D H W storage cylinder connection...

Page 2: ...18 1 1 13 GAS CONNECTION 19 1 1 14 ELECTRICAL CONNECTION 19 1 1 15 OPTIONAL ELECTRICAL CONNECTIONS 20 1 1 16 DHW SENSOR INSTALLATION 21 1 1 17 FUME EXHAUST FITTINGS 22 1 1 18 TYPES OF FUME EXHAUST SY...

Page 3: ...MATION 56 3 USER SECTION 57 3 1 USE 58 3 1 1 GENERAL USE WARNINGS 58 3 1 2 CONTROL PANEL 59 3 1 3 DISPLAY ICONS 60 3 1 4 INFO MENU DISPLAY DATA 61 3 1 5 START UP 62 3 1 6 OPERATING MODE 62 3 1 7 INFOR...

Page 4: ...es are differentiated by thickness and size in accordance with their hierarchy The images contain important parts described in the text marked with numbers or letters See chap chapter name this entry...

Page 5: ...mentation without any obligation to third parties neither will the company be held responsible for any inaccuracies in this handbook deriving from printing or translation errors the material and intel...

Page 6: ......

Page 7: ...be performed only by qualified personnel having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water productio...

Page 8: ...wer and performance The location must be properly vented through an air vent The air vent must be placed at floor level to prevent it from being obstructed protected by a grid that does not hamper the...

Page 9: ...If the temperature in the boiler installation location goes below 10 centigrades please fill the plant with anti freeze liquid and insert and electrical resistances kit see chapter ANTI FREEZE PROTEC...

Page 10: ...ox woodencrate nails fasteners plasticbags expanded polystyrene etc must be kept out of the reach of children as they may be dangerous Therefore they should be dismantled suitably differentiating them...

Page 11: ..._EN 1 INSTALLATION INSTALLER 1 1 5 OVERALL DIMENSIONS 1 1 6 JIG 642 64 157 301 64 136 151 307 410 642 307 410 49 148 80 102 31 110 177 33 107 R RB G F A AB 123 R HEATING RETURN 3 4 G GAS 3 4 F COLD 1...

Page 12: ...ES The boiler must be installed only on a vertical solid wall able to sustain its weight In order to allow the access inside the boiler for maintenance operations you have to respect the minimum techn...

Page 13: ...the boiler to completed masonry works For machine positioning proceed as follows see fig 3 1 Trace a line using a spirit level min length 25 cm on the installation wall 2 place the top of the jig alon...

Page 14: ...properly inclined being levelled see fig 1 so as to allow the condense to drain 1 1 8 CIRCULATOR PREVALENCE FLOW DIAGRAM Appliance Loss fig 1 Wilo Yonos PARA MSL 12 6B 0 0 4 0 8 1 2 1 6 2 0 2 4 0 0 1...

Page 15: ...valve opening in case of plant overpressure DOMESTIC CIRCUIT In order to prevent limestone build up and damages to the domestic water heat exchanger the hardness of the domestic supply water should no...

Page 16: ...it in order to separate the heating circuit from the domestic circuit Before powering up the boiler fill the system as follows 1 slightly loosen the cap of the circulator jolly valve 1 fig 1 to releas...

Page 17: ...again the loading tap R until the pressure gauge indicates the value of 1 2 bar fig 4 1 1 11 FILLING THE CONDENSATE COLLECTION SIPHON Before starting the boiler you have to fill the condensate collec...

Page 18: ...ure goes below 5 C automatically starting the burner until the water reaches the temperature of 30 C The system starts even if on the display appears OFF as long as the boiler is connected to the powe...

Page 19: ...TRANSFORMATION the gas supply pressure falls within the values indicated on the data plate 1 1 14 ELECTRICAL CONNECTION DANGER The equipment is electrically safe only if it is properly connected to a...

Page 20: ...17 use the electronic board placed inside the control panel as follows DANGER Cut off the voltage from the main switch remove the boiler s front casing refer to chapter ACCESSING THE BOILER remove the...

Page 21: ...panel see Paragraph ACCESSING THE BOILER Grasp the left and right control panel support brackets see fig 1 and pull them outwards at the same time rotating the panel downwards Take the 8 m length DHW...

Page 22: ...rds so as to favour the reflux of the condensate towards the combustion chamber suitably realized to collect and drain acid condensate For all air suction ducts with regard to the air path you should...

Page 23: ...ntake for combustion through co axial ducts the external one for air intake the plastic internal one for fumes discharge PLEASE SEE THE MAXIMUM DISCHARGE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA...

Page 24: ...ischarging fuel gas and air suctioning for combustion through two separated ducts PLEASE SEE THE MAXIMUM DISCHARGE AND INTAKE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximum discharge and in...

Page 25: ...ion through co axial ducts the external one for air intake the plastic internal one for fumes discharge PLEASE SEE THE MAXIMUM DISCHARGE LENGTH IN THE TABLE IN CHAPTER TECHNICAL DATA The maximum disch...

Page 26: ......

Page 27: ...s described below relative to first start up maintenance and replacement should be performed only by qualified personnel and authorized by RADIANT BRUCIATORI S p A 1 SUPPORT CENTRE SECTION 2 SUPPORT C...

Page 28: ...correct make sure that the grounding system works properly make sure that the combustion air adduction and fumes and condensate discharge take place properly in compliance with the Local and National...

Page 29: ...ivate the circulating pump automatic reset again further 3 minutes and switch off the power supply and switch it on again Open the gas tap Use the button to select the desired operation mode If the sy...

Page 30: ...ndicated in chapter Technical data otherwise adjust using a 40 Torx wrench the screw 2 fig 2 of the Off Set adjuster To increase the CO2 value turn the screw clockwise and vice versa if you want to de...

Page 31: ...NG AND PROGRAMMING THE PARAMETERS To access the parameters menu and adjust their values follow the procedure below 1 Press the button to select the OFF mode 2 Press and hold both the and heating circu...

Page 32: ...parametri_MIAB_R7_EN 2 FIRST START UP SUPPORT CENTRE 4 Keep the button pressed until the parameter value is displayed 5 Use the and buttons of the heating circuit to change the parameter value 6 Keep...

Page 33: ...24 B RAD ING Manuale 2007 1_SK 3_MIAB3013_R7_VK42_B3 2 Accesso e programmazione dei parametri_MIAB_R7_EN 2 FIRST START UP SUPPORT CENTRE 7 To quit the parameters menu press the button until OFF is dis...

Page 34: ...US WITH D H W PLATES EXCHANGER 02 ACCUMULATION 03 HEATING ONLY P02 GAS TYPE SELECTION ATTENTION READTHEINSTRUCTIONINCHAPTER GASTRANSFORMATION BEFORE CHANGING THIS PARAMETER 00 01 00 METHANE 01 LPG P03...

Page 35: ...IVERTER VALVE IN DOMESTIC POSITION FOR A PERIOD OF TIME EQUAL TO THE POST CIRCULATION SEE PARAMETER P09 SO AS TO MAINTAIN THE SECONDARY EXCHANGER HOT 00 01 00 DISABLED SET BY DEFAULT 01 ENABLED P07 HE...

Page 36: ...PARAMETER P00 AND ON THE GAS TYPE SEE PARAMETER P02 VALUE SET FOR PARAMETER P10 305 THE VALUE IS EXPRESSED IN HERTZ 1HZ 30 RPM P12 HEATING FAN MINIMUM SPEED ADJUSTMENT THROUGH THIS PARAMETER YOU CAN S...

Page 37: ...ION FOR STORAGE BOILERS ONLY THROUGH THIS PARAMETER YOU CAN ACTIVATE DEACTIVATE THE ANTILEGIONELLA HEAT TREATMENT OF THE STORAGE TANK AND SET THE DAYS AFTER THAT THIS FUNCTION CAN BE AUTOMATICALLY ACT...

Page 38: ...GREE THE VALUES OF THE DELIVERY TEMPERATURES TM REFER TO STANDARD SYSTEMS 30 80 C OR FLOOR SYSTEMS 25 45 C THE SYSTEM TYPE CAN BE SET FROM PARAMETER P03 00 30 SET BY DEFAULT AT 15 THE NUMBERING OF THE...

Page 39: ...DURING A REQUEST TO OPERATE IN HEATING MODE 70 100 THE VALUE IS EXPRESSED IN PERCENTAGE P20 CONTROL PERIOD T DELIVERY RETURN ONLYWITHMODULATINGPUMPANDRETURNPROBECONNECTED THROUGH THIS PARAMETER YOU CA...

Page 40: ...START UP SUPPORT CENTRE 2 1 6 ELECTRIC FAN FREQUENCY HEAT CAPACITY DIAGRAM GAS TYPE MINIMUM FREQUENCY MAXIMUM FREQUENCY STARTING STEP ADJUSTMENT G20 Hz 68 260 150 G30 Hz 65 235 G31 Hz 65 260 G30 G20 G...

Page 41: ...check the integrity and the position of the sealed chamber sealing gasket check the primary exchanger if necessary clean it check the operation of the gas light up and safety systems If necessary rem...

Page 42: ...5 5 Maximum combustion Performance 97 4 Fumes temperature at nominal heat capacity C 80 26 Fumes temperature at minimum heat capacity C 65 7 CO2 at nominal heat capacity G20 9 3 9 1 CO2 at minimum hea...

Page 43: ...or duct m 70 Max discharge length 60 100 Vert Co ax m 10 Max discharge length 80 125 Vert Co ax m 12 Max discharge length 50 50 Vert Split m 26 Max discharge length 60 60 Vert Split m 60 Max discharge...

Page 44: ...eaters Useful heat output At rated heat output of cogeneration space heater with supplementary heater disabled PCHP100 Sup0 kW At rated heat output of cogeneration space heater with supplementary heat...

Page 45: ...on heaters HQHUJ H FLHQF FODVV HFODUHG ORDG SUR OH Daily electricity consumption Qelec kWh Annual electricity consumption AEC kWh DWHU KHDWLQJ HQHUJ H FLHQF wh Daily fuel consumption Qfuel kWh Annual...

Page 46: ...CHANGER 3 BURNER UNIT 4 DETECTION ELECTRODE 5 LIGHT UP ELECTRODE 6 PROPORTIONAL VENTURI 7 SAFETY VALVE 3 bar 8 AIR RELIEF VALVE 9 CIRCULATOR 10 GAS VALVE 11 SYSTEM DRAINING TAP 12 SAFETY THERMOSTAT 13...

Page 47: ...LOW 1 FUMES SAFETY THERMOFUSE 2 HEAT EXCHANGER 3 BURNER UNIT 4 ELECTRIC FAN 5 GAS VALVE 6 AIR RELIEF VALVE 7 CIRCULATOR 8 SAFETY VALVE 3 bar 9 SYSTEM DRAINING TAP 10 SAFETY VALVE 8 bar 11 DOMESTIC CIR...

Page 48: ...PM MODULATING PUMP SRI RETURN SENSOR AR ORANGE VG GAS VALVE SR HEATING PROBE L LINE GI YELLOW TRA START UP TRANSFORMER SS DOMESTIC CIRCUIT PROBE N NEUTRAL BI WHITE TF FUMES THERMOFUSE 102 C EV ELECTRI...

Page 49: ...e front panel To intervene on the front of the boiler proceed as follows remove the fastening screws 1 fig 1 placed on the lower edge of the front panel grab the front panel from the bottom and remove...

Page 50: ...order ot intervene on the wirings of the control panel please proceed as follows DANGER Cut off the voltage from the main switch Grab at the same time the support brackets of the control panel fig 1 l...

Page 51: ...outlet and connect the other end of the tube to a suitable discharge turn the discharge tap of the system RS fig 1 open the relief valves of the radiators starting from the one at the top and continu...

Page 52: ...ADJUST MINIMUM OR SLOW LIGHT UP VALVE INFEED PRESSURE TOO HIGH ONLY FOR GPL BOILERS CHECK THE MAXIMUM ADJUSTMENT PRESSURE WITH FLAME LIGHT UP NEUTRAL AND PHASE INVERTED POWER SUPPLY PROPERLY CONNECT...

Page 53: ...THE SYSTEM AUTOMATIC WATER PRESSURE SWITCH CABLE DISCONNECTED CHECK THE WIRING WATER PRESSURE SWITCH BROKEN REPLACE IT E05 HEATING PROBE BROKEN OR INCORRECTLY CALIBRATED PROBE RESISTANCE VALUE 10 KOHM...

Page 54: ...MANUAL RESET CUT OFF THE TENSION E31 REMOTE CONTROLLER INCOMPATIBLE INDICATES THAT THE REMOTE CONTROLLER CONNECTED TO THE BOILER IS NOT COMPATIBLE WITH THE CIRCUIT BOARD REPLACE IT WITH A COMPATIBLE M...

Page 55: ...HEN THE D H W SENSOR DETECTS A TEMPERATURE OF 5 C THE BOILER OPERATES AT MINIMUM GAS PRESSURE WITH THE DIVERTER VALVE IN THE SUMMER POSITION THE FUNCTION IS DISABLED WHEN THE TEMPERATURE DETECTED BY T...

Page 56: ...ts 2 and re tighten the coupling 3 see fig 1 CONVERSION TO NATURAL GAS Remove the diaphragm 1 and re tighten the coupling 3 see fig 1 Remount the components following the demounting operations in reve...

Page 57: ...are addressed to all those who will use the machine The machine must be used and accessed only by qualified operators that fully read and understood the User section paying particular attention to th...

Page 58: ...r property due to incorrect use DANGER The boiler should not be used by persons including children with reduced physical sensory or mental capacities or without suitable knowledge or experience unless...

Page 59: ...nello comandi_combinata_MIAB_R7_EN 3 USE USER 3 1 2 CONTROL PANEL KEY 1 DOMESTIC HOT WATER TEMPERATURE ADJUSTMENT KEYS 2 OPERATING MODE SELECTION KEY SUMMER HEATING ONLY WINTER OFF 3 RESET KEY ANOMALY...

Page 60: ...IAB_EN 3 USE USER 3 1 3 DISPLAY ICONS KEY 1 INDICATION OF PARAMETER NUMBER OR DISPLAYED INFO CODE 2 FLAME PRESENT SIGNALLING 3 ERROR DISPLAY THAT CAN BE RESET 4 OPERATION IN HEATING MODE ENABLED 5 PAR...

Page 61: ...cuit for 2 seconds It will be displayed the info code alternated to the associated value Use keys and of the heating circuit to scroll through the list of displayed data To exit display mode press the...

Page 62: ...nabled Whenever heating energy is needed to heat the rooms the automatic start up system will start the burner this is indicated by displaying the symbol blinking WINTER MODE In this mode the boiler m...

Page 63: ...e proceed as follows contact the Technical support centre that will empty the water system where no anti freeze is intended and will cut off the power water and gas supply Or leave the boiler in OFF o...

Page 64: ...e sure using pressure gauge M fig 1 that the system pressure reaches 1 2 bar see fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressur...

Page 65: ...NICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CONTACT THE TECHNICAL SUPPORT CENTRE E04 WATER MISSING IN THE SYSTEM IF THE SYSTEM PRESSURE IS BELOW 1 2 BAR FILL THE SYSTEM AS DESCRIBED IN CHAP...

Page 66: ...lie_combi_MIAB3013_EN 3 USE USER CODE FAULT INTERVENTION E99 GENERAL INTERNAL BOARD ERROR CUT OFF THE POWER SUPPLY FROM THE MAIN SWITCH AND THEN RESTORE IT AS SOON AS THE ERROR CODE DISAPPEARS THE BOI...

Page 67: ...R 3 1 10 ACTIVE FUNCTIONS SIGNALLING CODES CODE FUNCTION INTERVENTION F08 H E A T I N G A N T I F R E E Z E FUNCTION ACTIVE WAIT UNTIL THE OPERATION IS COMPLETED F09 D H W CIRCUIT A N T I F R E E Z E...

Page 68: ...er of the device using a wet cloth and come neutral soap WARNING DONOTuseabrasiveorpowderdetergents as they might damage the plastic cover and control elements 3 1 13 DISPOSAL The boiler and all its a...

Page 69: ......

Page 70: ......

Page 71: ......

Page 72: ...RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 39 0721 9079279 e mail info radiant Internet http www radiant it...

Reviews: