INITIAL PILOT LIGHTING

A. TOP BURNERS / RAISED GRIDDLE-BROILER

All Radiance appliances are adjusted and tested before leaving the factory, effectively matching 
them to sea level conditions. Adjustments and calibrations to assure proper operation may be 
necessary on installation to meet local conditions, low gas characteristics, to correct possible 
problems caused by rough handling or vibration during shipment, and are to be performed only by
qualified service personnel. These adjustments are the responsibility of the customer and/or dealer 
and are not covered by our warranty.
Check all gas connections for leaks with a soapy water solution before lighting any pilots. DO NOT 
USE AN OPEN FLAME TO CHECK FOR LEAKS! Putting an open flame beside a new gas connec-
tion is extremely dangerous.
Before lighting any pilots, make sure that burner valves and thermostats are turned "off".

All top section burners are equipped with constant-burning pilots. These are to be manually lighted 
immediately after the gas is turned on and the system is checked for leaks. Burner pilots are 
provided for each burner and can be rechecked for proper adjustment. Adjustments can be made 
with a screwdriver to the brass pilot valve accessible through the valve cover.

B. HOT TOP

The pilot should be lighted immediately after the gas is turned on and the system is checked for 
leaks. The pilot can be reached with a long match through the valve cover, or by lifting the plate 
upward and accessing through the top.

C. GRIDDLES

The griddle pilot is ignited in the same fashion as the Hot Top section, using a long lighted match 
placed through the front control panel opening. Adjustment of the pilot flame can be made with a 
screwdriver to the pilot valve, accessible through the valve cover.

For detailed service instructions to adjust by-pass(minimum burner) flame and to recalibrate oven 
and griddle thermostatic controls.

When lighting pilots and checking for leaks, do not

stand with your face close to the combustion chamber.

CAUTION

Summary of Contents for TARG-6B24RG

Page 1: ...ed shut down units at main shutoff valve and contact the local gas company or gas supplier for service FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity...

Page 2: ...ore leaving factory The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment if shipment arrives damaged 1 VISIBLE LOSS OR DAMAGE Note on freight bill...

Page 3: ...off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2PSI 5 Please contact the factory the factory representative or a local service company...

Page 4: ...r if the range should move suddenly while being pushed unto position by hand HIGH SHELF ASSEMBLY 1 Mount the high shelf riser to the range with 10 sheet metal screws pointed tips in the back 2 Mount t...

Page 5: ...pt clear to avoid any obstruction of the flow of combustion and ventilation air Adequate clearance must be maintained at all times in front and the sides of the appliances for servicing and proper ope...

Page 6: ...mally supplied by the installer however a pressure regulator is packed inside each Radiance Range The regulators supplied for Radiance Ranges have 3 4 inlet outlet openings and are adjusted at the fac...

Page 7: ...regulator will void the warranty The arrow on the bottom of the regulator should be pointing toward the unit The regulators supplied with ranges have NPT connections Be sure the regulator matches the...

Page 8: ...tors for Movable Gas Appliances ANSI Z21 69 and addendum Z21 69a or latest edition and a quick disconnect device that complies with the standard for quick disconnect devices for use with Gas Fuel shou...

Page 9: ...are equipped with constant burning pilots These are to be manually lighted immediately after the gas is turned on and the system is checked for leaks Burner pilots are provided for each burner and can...

Page 10: ...eck near the floor area for the odor of propane gas before attempting to light any pilot burners 4 Depress the button on the safety valve and hold it in throughout the lighting procedure 5 Light the p...

Page 11: ...dle surface thoroughly with hot soapy water to remove the protective oil coating wiped on at the factory 2 Rinse with a mixture of 1 4 cup vinegar to one quart water 3 Spread unsalted solid shortening...

Page 12: ...e ALL OVENS AND SALAMANDER BROILERS 1 Remove the baking racks Wash in hot soapy water and replace after the rest of the oven is cleaned 2 Remove the oven bottom by lifting it out from the front then s...

Page 13: ...d efficient operation at least yearly by a qualified service company STAINLESS STEEL All stainless steel body parts should wiped regularly with hot soapy water during the day and with a liquid cleaner...

Page 14: ...e for service parts and labor charges performed by non authorized service companies All claims should include the model number serial number proof of purchase date of installation and all pertinent in...