RADIANQBIO INSTRUMENT www.radian21.com
27
F-30. DAC mode (Setting Analog output type)
①
RI-10W, RI-25W, RI-27W, RI-50W, RI-148A,B
(Standard setup value : b_10V)
Display data
Setting
b_05v
-5 ~ +5V output
bidirectional, polarity
b_10v
-10 ~ +10V output
b_02A
0 ~ 20mA output
unidirectional, unipolar
b_42A
4 ~ 20mA output
U_05v
0 ~ 5V output
bidirectional,
unipolar
U_10v
0 ~ 10V output
U_02A
0 ~ 20mA output
U_42A
4 ~ 20mA output
② RI-20W, RI-30W
(Standard setup value : b_10V)
Display data
Setting
b_05v
0 ~ 5V
output
unidirectional, unipolar
b_10v
0 ~ 10V
output
b_02A
0 ~ 20mA
output
b_42A
4 ~ 20mA
output
U_05v
0 ~ 5V
output
bidirectional,
unipolar
U_10v
0 ~ 10V
output
U_02A
0 ~ 20mA
output
U_42A
4 ~ 20mA
output
F-31. DAC capacity (Analog Outupt value setup)
(Standard setup value : 30000)
Display data
Setting
0
Set the rated capacity of the Analog output
< If Setting value 10000>
Display
data
F-30
setting data
b_05v b_10v b_02A b_42A U_05v U_10v
U_02A
U_42A
-10000
-5V
-10V
0
4mA
0
0
0
4mA
0
0
0
0
4mA
2.5V
5V
10mA
12mA
10000
+5V
+10V
20mA
20mA
5V
10V
20mA
20mA
~
+99999
Note) Models RI-20W and RI-30W cannot be negative (-) output.