background image

6

• 

Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 4. Never install 

the product so that the distance between the floor and the lower side of the product is less than 30cm:

 -

Remove the wall-mounting bracket fixed to the back of the radiator, by releasing the 2 lower springs;

 -

Use a pencil to mark the position of the fixing points (picture 5).

 -

Drill the 4 holes at the points marked previously, and insert the plastic anchors; 

 -

Fix the bracket to the wall using the 4 screws supplied (picture 6);

 -

Hook the radiator to the bracket starting with the 2 upper fixing points, and then click the 2 lower fixing points into 

position (picture 7);

 -

Should you have to remove the radiator from the bracket at a later stage, we recommend releasing the lower two 

fixing points first and then the upper fixings.

4. 

TOWELS

• 

Always outspread the towels over the support bars (picture 8-A);

• 

Do not place the towels on top of the product (picture 8-B);

• 

Do not roll up the towels between the bar and the front surface (picture 8-C).

5. 

Command description and functioning

• 

The following controls  are available on the front panel (picture 9):

A -   Stand-by

B -   Increase

C -   Decrease

D -   Mode

E -   Display 

The product can be operated in 3 different modes: automatic, programmed or frost free.

Automatic Mode

In this mode the product works to reach and maintain the Comfort temperature set by the user. An automatic power manage-

ment system allows optimum control of consumption and precise adjustment of the comfort level automatically maintaining the 

selected temperature constant over time, in accordance with what has been set on the electronic thermostat.

In automatic mode is also available a special feature, which is activated at user’s choice, which allows to detect the possible 

opening of a window and force the functioning to the Frost free mode to minimize energy waste.

Programmed Mode

The product  can be programmed, on hour base, for each day of the week. For each hour of the day it is possible to define 

the reference temperature to be reached/maintained, choosing between Comfort, Eco (whose value is equal to the Comfort 

temperature reduced by 3,5°C) or Frost free.

In programmed mode the open window detection function is disabled so that the product can correctly follow the 

temperature profile defined by the user.

Frost free Mode

In this mode the thermostat is automatically set to maintain 7±3°C.

Summary of Contents for ONSEN

Page 1: ...ONSEN EN Please retain these instructions in a safe place for further reference...

Page 2: ...2 Volume 3 Volume 1 Volume 2 60cm 60cm 2 25m 60cm 1 1 2 2 3 3 4 4 min 15cm min 15cm min 30cm min 50cm min 15cm...

Page 3: ...3 6 6 9 9 5 5 6mm L 35mm A B C 8 8 OK NO NO 7 7 A B C...

Page 4: ...used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervi sion or instruction co...

Page 5: ...stant supervision is provided WARNING To reduce the risk of fire keep textiles curtains or any other flammable material a minimum distance of 1 m from the air outlet 2 Your product Other than the heat...

Page 6: ...ols are available on the front panel picture 9 A Stand by B Increase C Decrease D Mode E Display The product can be operated in 3 different modes automatic programmed or frost free Automatic Mode In t...

Page 7: ...omatic Programmed or Frost free mode as described in paragraph 5 Press the M key to switch from automatic to pro grammed mode The display shows Pr The clock symbol and the icon relating to the opera t...

Page 8: ...gs and resume the normal functioning OPEN WINDOW DETECTION This function makes it possible to detect an open window and automatically activate the Anti freeze operating mode When the function is enabl...

Page 9: ...after a previous change It is not possible indeed to evaluate the room temperature maintained by the product correctly if the comfort level temperature is continually changed in a short time If a diff...

Page 10: ...re can be changed by pressing the M key The lighting in sequence of the icons described above indi cates the reference temperature Use the and keys to view modify the temperature set for each of the h...

Page 11: ...Eliminate any other possible reasons for overheating e g obstructions in front of the air inlet outlet grilles build ups of dirt Turn on the radiator and check it works correctly If the touch control...

Page 12: ...e of heat output room temperature control select one At minimum heat output elmin 0 000 kW single stage heat output and no room temperature control no In standby mode elSB 0 343 W Two or more manual s...