BOOST FUNCTION

The Boost function allows you to activate timed operation at maximum power without the thermostat control. At the end of this 

forced operation, the heater returns to the operating mode prior to activation.
To activate the function press and at the same time the buttons 

 and 

M

. The default duration of 60min flashes on the di

-

splay. The duration can be chosen between the values   of 60, 90 or 120 minutes (2h) using the buttons 

 and 

. 5 seconds 

after the last selection the function is activated.

If the remaining time is less than or equal to 59min the display shows the remaining minutes of heating. If higher the display 

shows the remaining minutes preceded by the word "1h" shown for 3 seconds.

7. 

Troubleshooting

• 

In the event of overheating, the safety device on the appliance automatically disabled the heating element. In this case:

 -

Turn off the radiator and allow it to cool down for about 15/20 minutes.

 -

Eliminate any other possible reasons for overheating (e.g.: obstructions in front of the air inlet/outlet grilles, build-

ups of dirt).

 -

Turn on the radiator and check it works correctly.

• 

If the touch control commands are blocked or don't properly answer to digital pressure, turn off the heater for 1min and 

then try again. 

8. 

Maintenance

• 

This product does not require any special maintenance.

• 

Clean the product with a dry cloth once every 6 months.

• 

If the product requires repairing, contact an authorised technical service centre.

• 

When replacing the power cable, use a 2x1,00mm

2

 H05V2V2-F HAR type. This operation must be performed by qua

-

lified personnel and never by the end user in order to avoid damaging the appliance and jeopardising personal safety.

9. 

Legal notice

Environment and recycling

Please help us to protect the environment by disposing of the packaging in accordance with the national

regulations for waste processing.

Recycling of obsolete appliances

Appliances with this label must not be disposed off with the general waste. They must be

collected separately and disposed off according to local regulations. 

Summary of Contents for ONSEN

Page 1: ...ONSEN EN Please retain these instructions in a safe place for further reference...

Page 2: ...2 Volume 3 Volume 1 Volume 2 60cm 60cm 2 25m 60cm 1 1 2 2 3 3 4 4 min 15cm min 15cm min 30cm min 50cm min 15cm...

Page 3: ...3 6 6 9 9 5 5 6mm L 35mm A B C 8 8 OK NO NO 7 7 A B C...

Page 4: ...used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervi sion or instruction co...

Page 5: ...stant supervision is provided WARNING To reduce the risk of fire keep textiles curtains or any other flammable material a minimum distance of 1 m from the air outlet 2 Your product Other than the heat...

Page 6: ...ols are available on the front panel picture 9 A Stand by B Increase C Decrease D Mode E Display The product can be operated in 3 different modes automatic programmed or frost free Automatic Mode In t...

Page 7: ...omatic Programmed or Frost free mode as described in paragraph 5 Press the M key to switch from automatic to pro grammed mode The display shows Pr The clock symbol and the icon relating to the opera t...

Page 8: ...gs and resume the normal functioning OPEN WINDOW DETECTION This function makes it possible to detect an open window and automatically activate the Anti freeze operating mode When the function is enabl...

Page 9: ...after a previous change It is not possible indeed to evaluate the room temperature maintained by the product correctly if the comfort level temperature is continually changed in a short time If a diff...

Page 10: ...re can be changed by pressing the M key The lighting in sequence of the icons described above indi cates the reference temperature Use the and keys to view modify the temperature set for each of the h...

Page 11: ...Eliminate any other possible reasons for overheating e g obstructions in front of the air inlet outlet grilles build ups of dirt Turn on the radiator and check it works correctly If the touch control...

Page 12: ...e of heat output room temperature control select one At minimum heat output elmin 0 000 kW single stage heat output and no room temperature control no In standby mode elSB 0 343 W Two or more manual s...

Reviews: