If the value is set to 0, it means that the timer is not set. The digital tube displays the ambient temperature 

immediately if there is no operation in 5 seconds or any other button is pressed within 5 seconds.

• 

(Digital tube) normal display: If the timer is not set, the digital tube always displays the current ambient tem-

perature, the unit “°C/°F” lights up, and the display range is (-9°C~40°C) (10°F~99 °F), (LO displays when the 

temperatures is below -9°C/10°F, and HI displays when the temperatures is above 40°C/99°F). If the timer is 

set, the ambient temperature is displayed for 5 seconds and then the remaining time is displayed for 5 seconds 

alternately.

TIMER ON FUNCTION

• 

Press the “TIME” button in the standby state to make the digital screen and the timer icon display the status; 

the digital tube will turn on and off in 0.5 seconds. At this moment, the TIME button can be used to set the time 

to 12H→11H→10H→9H→8H →7H→6H→5H→4H→3H→2H→1H→0H→12H→11H→10H→ ...; the step size 

is 1 hour, and the prefix 0 is not displayed. When the TIME button is pressed for more than 3 seconds, the 

schedule power-on is turned off.

• 

If the schedule time is set to 0, it means that schedule power on is turned off, and the system will enter standby 

state if there is no operation in 5 seconds. After schedule power-on is set, the digital tube will stop flashing and 

start timing if there is button operation in 5 seconds or any button except the power button is pressed down. At 

this moment, only the schedule time is displayed, and the ambient temperature isn’t displayed. Press the power 

button during the schedule setting or timing, the system will start normally, run according to the current preset 

function, and the schedule time will not be memorized.

• 

The default working state turns on when the power is turned on for the first time.

• 

Set schedule power on after normal shutdown (power isn’t turned off). At this moment, the working status is the 

state before shutdown. For example, if the cooling mode is turned on when the power is turned off last time, 

the cooling mode is also turned on when the power is turned on again. (Note: This timer set before the last 

shutdown won’t be saved.)

• 

When the timer/schedule button is pressed, the corresponding function indicator flashes (1HZ); for example, if 

high speed and cooling function are set at the last shutdown, the timer/schedule indicator is always on and the 

high speed ind cooling indicator flash. After the machine is turned on, the MCU starts to detect whether 

there is water in the water tank when the pump has been running for 5S. If the software detects that the water 

shortage protection switch is off (water shortage) for 5S, the water pump stops working; the buzzer beeps and 

alarms 10S (software control).

• 

When the schedule power on/off button is pressed, the function that will be turned on after power on will flash 

at 1HZ, but the user can also switch to desired working status, e.g. switching from high speed to low speed 

or cooling mode; the schedule power off can’t be saved or operated (the scheduled function flashes at 1HZ if 

there is no button operation after 3S, or flashes immediately if any other button is pressed) The timing error is 

within ±3%.

6. 

COOLING/HUMIDIFYING

In the working state, press the “Cooling/humidifying” button to control the on/off of the pump. inside the machine.

When the cooling mode is turned on, the product starts to detect whether there is water in the water tank when the 

pump has been running for 5S. If the unit detects that the water shortage protection switch is off (water shortage) for 

5S, the water pump stops working; the buzzer beeps and alarms 10 times.

7. 

VERTICAL SWING

In the working state, press the “Vertical swing” button to turn on the up-down swing.

8. 

HORIZONTAL SWING

In the working state, press the “Horizontal swing” button to turn on the left-right swing.

SPEcIAL FUNcTIONS

POWER FAILURE MEMORY FUNCTION

• 

In the power-on state, when the power is restored after power off, the device beeps 10 times (once per se-

cond), no display or operation; it restores the last power-on state after 30 seconds (all functions are restored, 

including the new long-term work protection function).

• 

If you press the power button during the recovery time, the last state is restored immediately.

• 

Countdown of the timer function /delay start function also needs to remember. The error of each power failure 

shouldn’t exceed 5 minutes (ignoring the power outage time).

• 

The power-off memory function isn’t available when the power is turned on again after normal shutdown.

Summary of Contents for AER Max

Page 1: ...AER Max IT Leggere il manuale d uso Conservare con cura le istruzioni per ogni futura consultazione EN Please retain these instructions in a safe place for further reference...

Page 2: ...o l umidit e la temperatura dell acqua presenti nel serbatoio e dandovi una piacevole sensazione di fresco Per la vostra sicurezza Questo prodotto non adatto per l utilizzo su veicoli imbarcazioni o a...

Page 3: ...svolte regolarmente Assicuratevi che le ruote siano bloccate quando il prodotto in funzione Non lasciate che animali o bambini giochino con il prodotto men tre in funzione Non utilizzate questo prodot...

Page 4: ...Blocco automatico del funzionamento della ventilazione raffrescata in caso in cui l acqua nel serbatoio sia infe riore al minimo consentito Serbatoio capiente Spegnimento automatico in caso di 15h di...

Page 5: ...si porta in modalita STAND BY 3 ACCENSIONE e SPEGNIMENTO ON OFF Dallo stato di STAND BY premere il tasto ON OFF per accendere il prodotto L apparecchio si mette in funzione a velocit SILENZIOSA ed a d...

Page 6: ...di temporizzazione conferma che la procedura si conclusa correttamente Per disattivare la funzione di ACCENSIONE TEMPORIZZATA tenere premuto il pulsante TIME fino a quando non si spegne il display Se...

Page 7: ...enza operazioni di controllo interazioni con pannello comandi o telecomando spegnendo automaticamente il prodotto Se si desidera annullare questa funzione tenere premuto i pulsanti COOLING HUMIDIFYING...

Page 8: ...che sentiate un leggero odore dell aria Questo non assolutamente tossico e scomparir dopo breve tempo Non spruzzare l acqua sul motore o su altri parti elettriche Non superare il livello massimo indi...

Page 9: ...rmine dello svuotamente Riporre il prodotto in un sacchetto e custodirlo in un luogo asciutto e ventilato Dati tecnici Modello AER Max Voltaggio 230V AC Frequenza 50Hz Potenza 250W Rumorosit 75dB Dime...

Page 10: ...d for use in vehicles or on board ships or aircrafts This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental ca pabilities or lack of exp...

Page 11: ...uch as curtains near the product when it is in operation Do not ingest battery In case of involuntary ingestion of the bat teries seek immediate medical attention When not in use keep the product with...

Page 12: ...panel 4 Front shell 5 Water tank 6 Water gauge 7 Casters 8 Buttons 9 Button panel 10 Wet curtain cover 11 Side shell 12 Top cover 13 Remote controll 14 Rear window 15 Wet curtain 16 Rear shell 17 Wate...

Page 13: ...wind speed in the following sequence low medium high low medium and so on Low Medium High 5 TIME In the working state this button is the timer button which allows setting the timer to 1 12 hours in st...

Page 14: ...When the timer schedule button is pressed the corresponding function indicator flashes 1HZ for example if high speed and cooling function are set at the last shutdown the timer schedule indicator is a...

Page 15: ...ER If you need to turn on the cooling and humidification function please add water to the water tank It is possible to add water to the tank either using a container or using a tube FILLING BY CONTAIN...

Page 16: ...cal parts Do not exceed the maximum level indicated Use only drinking water Do not leave the water hose permanently connected to the product REMOTE CONTROLL Open the battery cover Install a battery of...

Page 17: ...the water plug Wrap the machine to prevent dust from entering and store it in a dry and ventilated place Technical data Modell AER Max Rated voltage 230V Rated frequenzy 50Hz Rated power 250W Noise 7...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ISMAX001_R1...

Reviews: