10
Owner’s Manual:
1015
1784593 Rev AD
ECO 18-0069
July 2020
www.radiaproducts.com (PHONE) 800-221-1083 | (INTL) +1-763-533-2969 | (FAX) 763-533-0015
PROBLEM
CAUSE
REMEDY
Not connected to power source
Building ciruit breaker or fuse blown
Machine door does not make
contact with limit switch
Motor Thermal Protector Activated
Pail damaged
Faulty controller
Faulty door limit switch
Bearings worn or damaged
Connect to power source
Reset breaker or replace fuse
Adjust lever arm on the switch to make
contact with door bracket tab when
door is closed
Fix or replace pail
Contact Radia Customer Care
Contact Radia Customer Care
Contact Radia Customer Care
Machine won't operate
Excessive Vibration
Machine doesn't shut off
at end of mixing cycle
Machine doesn't shut off
when door is opened
Increasing mechincal
noise
6. Troubleshooting
6. Troubleshooting
Disconnect the machine from its power source before servicing.
Allow to cool, then restart the machine
Faulty motor
Contact Radia Customer Care
Contact Radia Customer Care
Worm, Damaged, or Loose
drive belt
Pail not properly seated
Feet are not level
Reset pail into holder
Adjust and level feet
Faulty controller
Faulty door limit switch
Contact Radia Customer Care
Contact Radia Customer Care