24
EN
With the cord-switch
setting unit
With the set button on the
tubular motor
OR
With the universal
setting cable
10. Manual adjustment of end points
1.
Move the roller shut-
ters in the desired
direction.
Recommendation
First in upright
position.
2.
In addition ...
3.
Release the button
again as soon as the
desired end point is
reached.
4.
You can correct the
end point in small
steps by briefly
pressing the button.
SET
or
5.
Switch off the
specified direction of
travel after success-
fully setting the end
points.
The respective end
point is stored.
press the set button
on the tubular motor.
ON
SET
or
Reset the original connection in accordance with the connection diagram [ 26 ] on page 21, if you have car-
ried out the setting with the universal setting cable or with a cord-switch setting unit.
SET
Set the Venetian blind
switch to the neutral
position and release the
set button.
i
In the event that a malfunction occurs during the setting process, e.g. the tubular motor only runs for a single rota-
tion even when you press and hold the set button, the adapter
(10)
may have slipped off the drive head
(12)
.
Check and, if necessary, correct the positioning of the adapter
(10)
SET
ON
ON
ON
Direction of travel 1
Direction of travel 2
With the SET button or ON switch
(direction of travel 1 or 2)
press/tap the ON switch or SET but-
ton for the opposite direction twice
briefly and engage/press and hold
the third time.
Set the switch to the centre
position and ..
release the SET button.
Direction
of travel 1
press/tap twice
briefly and
press and hold
the third time.
Set the rocker
switch to the
centre position.
Direction
of travel 2
II
I
I
III
III
III
II
I
OR
or