  CAUTION!

Risk of crushing injuries to the hand when work-
ing with the roller shutter box open. 

 

‹

Never reach into the area of the winding shaft 
when the motor is running.

  ATTENTION!

The roller shutter may be damaged in case of 
incorrect manual adjustment of the end points.

 

‹

Never dismantle the mechanical stoppers or the 
end rail from the final roller shutter slat.

 

‹

 Do not allow the shutter to knock against the 
mechanical stoppers and maintain a safety gap 
of 2 - 3 cm.

9.  Self-learning mode with smooth stop

 

   WARNING!

WARNING!

Risk of fatal injury (electric shock) due to tear-
ing off the motor cable (15).

 

‹

Ensure that the motor cable 

(15)  

is not taken up by the winding  
shaft 

(5)

 or torn off during the setting process.

Important conditions for adjusting  
the end points and for safe operation

 

‹

 End points must be set in order to switch off the 
motor when they are reached for both directions 
of travel, up ( )/down ( ).

 

‹

 The tubular motor must be fully installed.

 

‹

 There must be a suitably fixed limit (e.g. a win-
dow sill) in the area of the lower end point if the 
end point is to be set automatically.

You can also adjust the end points manually  
if required:

 

‹

Manual adjustment of the upper and lower end 
point, e.g. during the initial installation.

 

‹

Manual adjustment of an end point in combina-
tion with the self-learning mode.

The RolloTube M-line is delivered from the factory in 
self-learning mode with a smooth stop and can be 
put into operation immediately after the electrical 
connection.

10.  Manual adjustment of end points

1. 

Switch on the mains power supply.
The RolloTube M-line is ready for operation imme-
diately.

2. 

 

Move the roller shutter up and down.
The end positions for the smooth stop 
are automatically learned during the 
first run cycles.

3. 

Subsequently check the direction of travel of the 
roller shutter. 
Switch the lines for the rotation direction if the direc-
tion of travel is wrong, see connection diagram 

[ 26 ]

 

on page 21.

  ATTENTION!

The roller shutter may run into the roller shutter 
box in self-learning mode and be damaged with-
out stoppers or an end rail.

 

‹

Always fit two stoppers or an end rail to the roller 
shutter 

(17)

see page 18. 

 

‹

Never dismantle the mechanical stoppers or the 
end rail from the final roller shutter slat.

Initial installation

For initial installation, the roller shutter engineer 
can carry out the end point setting with the help 
of the 

set button (11) 

on the motor or with a com-

mercially available 

universal setting cable (21)

 or 

with a

 cord-switch setting unit

.

In order to do so, follow the more detailed informa-
tion provided in the operating manual of the respec-
tive accessories.

Subsequent modification of the end points with 
external controllers

If you want to subsequently modify the end points of 
your tubular motor, you can adjust these with your 
roller shutter controller (e.g. Troll Comfort).

Summary of Contents for RolloTube M-line

Page 1: ...e M line Small MLIS Medium MLIM Item numbers 2640 06 10 2640 10 10 2660 10 10 2660 20 10 2660 30 10 2660 40 10 2660 50 10 Please note Site of installation Serial number RolloTube M line Tubular Motors...

Page 2: ...ing shaft 15 7 9 Preparation for use of the precision tubes 15 7 10 Mounting the roller capsule 4 17 7 11 Mounting the motor into the bearings 17 7 11 1 Mounting into the drive bearing as a click bear...

Page 3: ...t i Further useful information Please read the respective manual Unauthorised handling or configuration i 1 This manual serves to describe the installation electrical connection and operation of RADEM...

Page 4: ...ions to prevent unintentional switching on Arrange to have the system checked by a skilled electrician Exceeding the maximum permissible running time KB transientoperation mayoverloadthe tubular motor...

Page 5: ...with a site provided isolating device fuse must be perma nentlyavailablefortheelectricalconnectionatthe installation location Therollershuttermustrunupanddownsmoothly It should not jam Operating cond...

Page 6: ...also used to find the end points amongst other things End points An end point is defined and set for each direction of travel of the roller shutter Once this point has been reached the tubular motor s...

Page 7: ...1 x 1 x d Click universal drive bearing 1 x e Click ready box support 1 x Please note Customer specific scope of delivery After unpacking please check the following Check that the package contents mat...

Page 8: ...inding shaft 6 Rigid shaft connectors or ties 7 Retaining clip 8 Catch 9 Tubular motor 10 Adapter 11 Set button 12 Drive head 13 Click drive bearing 14 Retaining spring 15 Motor cable 16 Controller e...

Page 9: ...Self learning mode with a smooth stop at both end positions see page 23 Torque monitoring Blockage detection in both directions of travel including reversing function Obstacle detection include rever...

Page 10: ...utomatically to the upper end stop the cycle for this is set at the factory The shutter length compensation operates automatically during normal operation so that generally you will not notice it If o...

Page 11: ...of the motor can be installed on either the right or left side of the roller shutter box These instructions depict the installation on the right hand side 7 1 Installation of the tubular motor Require...

Page 12: ...the winding shaft 5 to the required size Cut the shaft to size with a hacksaw at a right angle Remove the burrs from the shaft internally and ex ternally with a file 1 First determine the position of...

Page 13: ...10 1 Press the two retaining springs on the magnetic ring 18 downwards and pull the adapter 10 off the magnetic ring 18 Press the retai ning springs downwards 7 5 Dismantling the catch 8 The catch 8 c...

Page 14: ...ion then the catch 8 must be mounted with the freewheel mechanism original factory settings i If the catch 8 is mounted without the freewheel mechanism then the tubular motor will work without obstacl...

Page 15: ...ng shaft 5 will cause serious damage Never knock the tubular motor 9 with force into the winding shaft 5 1 First slide the catch 8 into the winding shaft 5 i The motor 9 must have sufficient free spac...

Page 16: ...imensions for the groove are depend ent on the tubular motor type used see figures 3 Slide the tubular motor into the precision tube 4 Mark the four fastening holes and subsequently drill them through...

Page 17: ...e drive bearing as a click bearing 13 1 Press the drive head 12 lightly into the click bear ing 13 until it engages The set button 11 must be easily accessible Hook the drive head 12 into the correspo...

Page 18: ...r shutter 17 ATTENTION Drilling and inserting screws in the area of the drive will cause the drive to be damaged Never drill or insert screws in the area of the drive 9 in order to secure the roller s...

Page 19: ...connector 6 Mounting roller shutter stoppers or an end rail 7 12 2 Mounting the roller shutter with ties 1 Slide the ties onto the uppermost slat of the roller shutter Place a tie every 40 cm into th...

Page 20: ...he roller shutter box so that they cannot be damaged by moving machinery The mains connection for the drive may only be connected with the same conduction type Con sult customer services if necessary...

Page 21: ...t setting of tubular motors connected in parallel RolloTube M line in self learning mode No end point setting required see page 23 RolloTube M line in parallel connection with other tubular motors The...

Page 22: ...Earth green yellow PE green yellow ON 8 4 Connection of a cord switch setting unit for manual end point setting 1 Pull out the mains plug or make sure that it is not plugged in 2 Open the terminal con...

Page 23: ...The RolloTube M line is delivered from the factory in self learning mode with a smooth stop and can be put into operation immediately after the electrical connection 10 Manual adjustment of end point...

Page 24: ...he universal setting cable or with a cord switch setting unit SET Set the Venetian blind switch to the neutral position and release the set button i In the event that a malfunction occurs during the s...

Page 25: ...necessary to connect the two control lines for up and down separately to the phase L Either use a new commercially available universal setting cable 21 or the older cord switch setting unit or an ext...

Page 26: ...e motor has cooled down The tubular motor stops after a short period of time during the setting and test procedures Possible cause The adapter 10 may have slipped off the mag netic ring 18 on the driv...

Page 27: ...after 180 seconds e g Basis for long term operation Basis 2 1 s Factor 86 2 1 s x 86 180 6 s Motor series MLIS xx xx PZ MLIM xx xx PZ Nominal torque Nm 6 10 10 20 30 40 50 No load speed rpm 28 16 16 1...

Page 28: ...h the Directives 2006 42 EC Machinery Directive and 2014 30 EU EMC Directive Warranty terms and conditions Information on our warranty conditions is enclosed separately with this product The full text...

Page 29: ...29 EN i...

Page 30: ...30 EN i...

Page 31: ...31 EN i...

Page 32: ...Subject to technical modifications misprints and errors Illustrations not binding RADEMACHER Ger te Elektronik GmbH Buschkamp 7 46414 Rhede Germany...

Reviews: