20
EN
27
(21)
26
8.4 Connecting a cord-switch setting unit for manual end point setting
1.
Open the terminal contacts by pressing the plung-
ers and connect all of the wires of the motor cable
(15)
corresponding to their functions, see also
figure
[ 23 ]
.
Pin assignment:
SET
Motor cable (15)
>
cord-switch
setting unit
L1
(black)
>
ON
(black)
L1
(brown)
>
SET
(white)
N
Neutral terminal (blue) >
N
(blue)
PE
Earth (green/yellow) >
PE
(green/yellow)
= direction of travel 1
= direction of travel 2
= no function
ON
8.3 Connection of the universal setting cable for manual
end point setting
1.
Open the terminal contacts by pressing the plung-
ers and connect all of the wires of the motor cable
(15)
with the same colours and corresponding to
their functions, see also figure
[ 23 ]
.
Pin assignment:
The connection is made with the same colours as the
motor connecting cable of the RolloTube C-line, see
figure
[ 23 ]
.
Button assignment for RolloTube C-line:
Button 1
= direction of travel 1 / 2
Button 2
= set button
Button 3
= no function
Button 1
Button 2
Button 3
Summary of Contents for RolloTube CLIS