3
Installation
2
EN
Installing the bearings
3.
◆
Install the new bearings in accordance with the previous position marks
of the old bearings. Make sure that the winding shaft can be installed
horizontally and that the first slat of the wound roller shutter casing is
perpendicular to the guide rail of the window.
◆
Fasten the bearings in accordance with the bearing type and on-site
conditions.
L = A - (B + C)
3
Determining the length of the winding shaft
4.
◆
Length of the winding shaft: L = A - (B + C)
◆
Installation up to a window width of 185 cm using the telescopic
shaft (5.1)
For installing window widths ranging from 105 cm to 185 cm, you can
pull the telescopic shaft
(5.1)
out of the octagonal winding shaft up to
the required length.
(5.2)
.
If the window is narrower than the winding shaft
(5.2)
, you will need
to shorten it to the required size. Cut both winding shafts to size with
a hacksaw at a right-angle. Remove the burrs from the edges of the
winding shafts internally and externally with a file.
Always observe a minimum insertion depth of 200 mm for the
telescopic shaft (5.1).
(7)
(8)
(5.2)
(9)
(5.2)
(11)
(15)
4
(10)
Sliding the tubular motor into the winding shaft
5.
ATTENTION!
Ensure that the adapter
(9)
does not slip off the adapter ring
(15)
on the
drive head
(11)
during the installation process, otherwise malfunctions may
occur.
Conditions of use and installation preparations
2.
◆
A continuous 230 V /50 Hz mains connection (L/N/PE) must be available
at the site of operation for the electrical connection of the tubular motor
in combination with on-site switchgear (fusing).
Please observe the installation and connection diagrams in the
enclosed operating manual for the tubular motor.