background image

2

EN

These instructions...

i

...give you a brief description of the installation of the RolloTube Automation 

Set.

These instructions do not replace the enclosed manual for the 

tubular motor.

Before you begin, please read these instructions through completely and 

follow all the safety instructions.

Damage resulting from non-compliance with these instructions and the safety 

instructions will void the warranty. We assume no liability for any consequential 

damage.

There is a risk of fatal injury from electric shock when working on all 

electrical systems.

   The electrical connection for the tubular motor and all work on the electrical 

systems may only be undertaken by an authorised electrician in accordance 

with the connection diagrams in the original manual for the enclosed tubular 

motor.

  Carry out all installation and connection work only when the product is 

disconnected from the mains power.

There is a risk of fatal injury in the event of failure to observe these 

instructions!
Observe the regulations for installing products in damp rooms. 

   Observe DIN VDE 0100, parts 701 and 702 in particular when installing the 

product in damp rooms. These regulations contain mandatory protective 

measures. 

Installation

  ATTENTION!

Never knock the motor (8) into the 

winding shaft (5.2) with force. 

Doing so will cause serious damage.

  ATTENTION!

Never drill in the area of the drive or 

insert screws in order to secure the 

roller shutter.

Removing the old roller shutter mechanism

  Open the roller shutter box.

   Close the roller shutter completely and release the roller shutter casing 

from the winding shaft.

   Then remove the existing belt winder and winding belt and close the belt 

inlet opening in the roller shutter box.

 CAUTION!

There is a risk of injury from the pre-tensioned spring in the old belt 
winder.

Hold the spring unit firmly when loosening the belt and allow it to recoil 
slowly until the spring unit has completely unwound.

1.

  Remove the winding shaft and all bearings.

(14)

1

(1)

(2)

(4)

(6)

(5.2)

(7)

(8)

(9)

(11)

(12)

(3)

(10)

(5.1)

(1)

 

Counter bearing 

(2)

 

Ball bearing

(3)

 

Axle pin on the roller capsule

(4)

 

Roller capsule

(5.1)

 

Telescopic shaft

(5.2) 

Winding shaft

(6) 

   

Ties or rigid shaft connectors

(7)

 Catch

(8)

 

Tubular motor

(9)

 

Adapter

(10)

   

Set button or 2 adjustment 

screws

(11)

 

Drive head

(12)

  Click drive bearing

(13) *

   Motor cable with/without 

connector, see page 1

(14)

 

Roller shutter casing

(13) 

*

i

  Mark the position of the centre of the old 

bearings so that you can install the new bearings 
and the winding shaft horizontally in the same 
position.

Summary of Contents for RolloTube Basic 2160 20 90

Page 1: ...Adapter catch Installation instructions Adjustment tool Click drive bearing Clamp bearing Octagonal winding shaft 60 mm x 0 6 Telescopic extension incl roller capsule Ties Counter bearing incl ball bearing Installation material in the accessory pack Application window width Standard 2660 20 00 M line Medium 20 Nm 16 rpm yes 1 1 1 1 1 1 4 1 1 Up to 185 cm EN Installation Instructions for the RolloT...

Page 2: ...ory protective measures Installation ATTENTION Never knock the motor 8 into the winding shaft 5 2 with force Doing so will cause serious damage ATTENTION Never drill in the area of the drive or insert screws in order to secure the roller shutter Removing the old roller shutter mechanism Open the roller shutter box Close the roller shutter completely and release the roller shutter casing from the w...

Page 3: ... the window is narrower than the winding shaft 5 2 you will need to shorten it to the required size Cut both winding shafts to size with a hacksaw at a right angle Remove the burrs from the edges of the winding shafts internally and externally with a file Always observe a minimum insertion depth of 200 mm for the telescopic shaft 5 1 7 8 5 2 9 5 2 11 15 4 10 Sliding the tubular motor into the wind...

Page 4: ...nter bearing 16 Warranty terms and conditions Information about the warranty conditions of our products can be found on our homepage 16 5 2 RADEMACHER Geräte Elektronik GmbH Buschkamp 7 46414 Rhede Germany Simplified EU declaration of conformity RADEMACHER Geräte Elektronik GmbH hereby declares that the radio tubular motors in the RolloTube S line DuoFern series comply with the Directives 2006 42 ...

Reviews: