According to DIN EN 13659, it is necessary to determine
that the movement conditions for the shutters are main-
tained in accordance with EN 12045.
2.1 Proper use
Only use the RolloTron Standard for opening and closing
roller shutters with a permissible belt.
Mechanical locks of any kind are not suitable for auto-
mated operation with this device.
Only use original spare parts
from RADEMACHER.
◆
By doing so, you avoid the risk of malfunctions and
damage to your RolloTron Standard.
◆
As the manufacturer, we provide no guarantee for the
use of third-party components and accept no liability
for consequential damage resulting from such.
◆
All repairs to the RolloTron Standard must be under-
taken by authorised customer service personnel.
Operating conditions
◆
Only operate the RolloTron Standard in dry rooms.
◆
A 230 V / 50 Hz power supply, together with a site-
provided isolating device (fuse, MCB), must be perma-
nently available at the installation location.
◆
An easily accessible 230 V / 50 Hz socket must be
available at the installation site if the enclosed
connecting cable with Euro plug is being used.
◆
The roller shutters must run up and down smoothly
and should not stick.
◆
The mounting surface for the RolloTron Standard
must be flat.
i
i
i
◆
The displacement must amount to at least 40 mm on
the lower edge in the rolled-out position with a force
of 150 N in the upwards direction.
◆
In doing so, it must be ensured that the extending
speed of the shutters for the final 0.4 m is less than
0.15 m/s.