NOTE
The door operator is preset to stage 3 by the supplier.
If required (e.g. if the power level is too low) you can
subsequently adjust the power limiting setting.
If the power level is too low, the door move-
ment will be impaired, particularly if the
mechanical structure of the door is not well
balanced.
2. Press „+“
(if necessary press several times)
until „4“ is displayed.
Adjust power limiting as required
3. Press „P“, the display
shows „7“ (stage 3).
4. Press „+“ or press „-“
to select the stage.
After a resetting of the power level, it is absolutely necessary to repeat the reference run for power
limiting and to conclude the programming again.
◆
During the reference run there is a risk of injury as the door operator develops
extremely strong forces.
◆
If the subsequent adjustment does not restore correct operation, please contact our authorised
Service department.
5. Press „P“, in order
to store the setting.
6. IMPORTANT
Repeat reference run
for power limiting
7. Conclude programming
method 1).
1. Press „P“ for
approx. 5 seconds.
Power level
Low
High
Factory setting
24