background image

42

Buttons

Indication in the display

Registr. with a Fernotron radio-controled tubul. motor with radio code

Call up the menu

1.

M

2.

3.

keep pressed

for approx.

2 sec.

M

OK

+

4.

/

OK

5.

/

OK

6.

M

/

Select expert mode (E)

The menu item flashes.

Open expert mode

It is important to press the buttons
in the correct order:

1. 

OK

   +  2. 

M

Select and open the radio code

Enter the 5-figure radio code for
the tubular motor and confirm
each figure with the OK button
(see page 48)

The tubular motor will be switched
on briefly in acknowledgement.
After this it will be in the SET mode
(input mode).You now have direct
contact with the connected tubular
motor.

Quit the menu

Summary of Contents for Fernotron Programming Centre

Page 1: ...Operating Instructions Fernotron Programming Centre Article No 2411 VBD 369 3 GB 06 09...

Page 2: ...entre art no 2411 complies with the requirements of the applicable European and national directives The conformity has been certified and the corresponding declarations and documentation are on file a...

Page 3: ...3 i General view Display Key see page 63 Receiver button Group button UP button OK STOP Stop button data trans mission Menu button OK button Auto Manu Down button Battery compart ment on the rear...

Page 4: ...r shutters Venetian blinds Electrical consumers e g lighting Operating conditions The Fernotron system may only be operated with and installed in systems and devices in which transmitter or receiver f...

Page 5: ...g the SET button 40 a Fernotron radio controlled tubular motor with radio code 42 Switching the button lock on or off 44 Expert mode 45 Calling up expert mode 46 Commissioning assistant 47 Selecting g...

Page 6: ...sists of various transmitters and receivers which allow you to adapt the system flexibly to your requirements Overview of Fernotron system The Fernotron system Group formation With the Fernotron syste...

Page 7: ...VER Saves the programm data Responds directly to radio command Article no 2420 Receiver surface mouned 2421 Receiver recessed version 2422 Receiver with local switch function 2423 Receiver with sensor...

Page 8: ...e registered once with each receiver see page 40 Functions The settings function which you can perform with the aid of the Programming Centre can be divided into the following types General functions...

Page 9: ...ding weekdays weekend programme individual days programme Individual functions apply for each of the maximum of 49 receivers Manual operation of individual roller shutters or devices AUTO MANU switcho...

Page 10: ...er Call up and carry out the commissioning assistant see page 17 Basic settings via menu navigation with standard switching times including allocation of the names and numbers of the groups and receiv...

Page 11: ...any changes in the table on page 14 Set the Programming Centre Call up and set the functions in the menu e g Set standard switching times or weekly timer Set the automatic sunlight protection mode dus...

Page 12: ...You can use names several times To distinguish between receivers with the same name each receiver is given a different receiver number In the living room there are 5 windows and all 5 windows should o...

Page 13: ...N 27 LAMP 28 FAN 29 AWNING 30 MEDIA ROOM 31 MOTOR 32 NORTH 33 FIRST FLOOR 34 EAST 35 PUMP 36 ROLLER SHUTTER 37 BEDROOM 38 STANDARD LAMP 39 SOUTH 40 PATIO 41 W C 42 STAIRWELL 43 CURTAIN 44 STORE 45 ENT...

Page 14: ...Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Group Standard pr Wp...

Page 15: ...Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name 7 Cod...

Page 16: ...es No DCF reception or weak DCF reception 1 to 2 lines in the display Confirm and automatically pro ceed with setting clock time and date see page 37 Good DCF reception 3 lines in the display Confirm...

Page 17: ...navigation Buttons Indication in the display Open the menu 1 M 2 3 Press for approx 2 sec M OK 4 OK 5 OK Select expert mode E The menu item flashes Open expert mode It is important that you press the...

Page 18: ...r all groups Select a name for each group see page 13 and confirm After each confirmation the next group will follow automatically Select a name for each receiver see page 13 and confirm ADVICE After...

Page 19: ...nds Register the Programming Cen tre with the receiver and begin data transmission Data transmission will take approx 5 seconds during which a count down from 5 down to 1 will be shown in the display...

Page 20: ...ta transmission to the last receiver return to the normal display ADVICE Abort initial operation By pressing the menu button the initial operation procedure will be aborted and the normal display will...

Page 21: ...3 4 5 6 7 8 Call up menu Select functionIf a function is selected then the corresponding symbol will flash Confirm the functionThe setting mode is activated and the value to be set flashes Select the...

Page 22: ...m function Transmit the time Data transmission Expert mode Automatic SU WI time changeover Set language Button lock Contrast DCF reception quality DCF clock Light function SU WI transmission time Movi...

Page 23: ...witched off only manual operation is possible AUTO MANU ADVICE Activating deactivating automatic operation for a receiver 2 OK Press for approx 1 sec Select the desired group and receiver Switch autom...

Page 24: ...us receivers in the group have different settings the AUTO and the MANU indication will appear in the display Activating and deactivating automatic operation AUTO Automatic operation on MANU Automatic...

Page 25: ...nu AUTO MANU Select the desired group and receiver Activating automatic operation AUTO Deactivating automatic operation MANU Example Group 5 window 3 patio Automatic operation is switched off After ev...

Page 26: ...d group Then press the E button several times until an A appears in the lower right hand side of the display A all receivers Activating deactivating auto matic operation for the whole group Quit the m...

Page 27: ...he same switching times for all days of the week ADVICE Buttons Indication in the display Changing the standard switching times for UP DOWN Open the menu 1 M Deactivating of switching times 2 3 4 OK 5...

Page 28: ...in a switching command Standardschaltzeiten AUF AB Gruppenfunktion The standard switching times are switched off OFF at first when you activate the weekly timer Accordingly only the switching times s...

Page 29: ...er Select group e g group 5 Select the operating mode Switch off weekly timer or Weekday weekend timer or Individual day timer Confirm the operating mode Set the weekday weekend timer Set the 1 openin...

Page 30: ...mes for each day of the week from Monday to Sunday Confirm each input with OK Setting the weekly timer 6 M Quit the menu ADVICE If the automatic data transmission was activated in expert mode see page...

Page 31: ...tic raising and lowering process once a set limiting value has been exceeded Light dependent control Principle of operation ADVICE Radio controlled solar light sensor 2440 Receiver e g 2420 INST SO PO...

Page 32: ...receiver Activating Deactivating the automatic sunlight mode On ON OFF OFF factory setting If desired select the next recei ver and activate deactivate the automatic sunlight protection mode or Quit t...

Page 33: ...ered the corresponding postcode in expert mode see page 51 no 8 factory setting 46 Buttons Indication in the display Activating deactivating the automatic dusk mode Open the menu 1 M 2 3 4 5 OK OK The...

Page 34: ...time incl time delay will be calculated for the current day ADVICE The latest lowering time is 23 59 6 OK 7 M Quit the menu ADVICE If the automatic data transmission was activated in expert mode see p...

Page 35: ...dom operation Open the menu 1 M 2 3 4 5 OK 6 M OK Select and open automatic random operation Select group and receiver Switch on automatic random operation On ON OFF OFF factory setting If desired sel...

Page 36: ...Time and date automatically to the receiver To do so you must activate and set the function SU WI transmission time in ex pert mode see page 52 54 IMPORTANT ADVICE Buttons Indication in the display Op...

Page 37: ...ived then it is not possible to alter the data ADVICE Buttons Indication in the display Setting and transmitting clock time date to receiver Open the menu 1 M 2 3 5 6 OK 4 OK STOP M OK Select and open...

Page 38: ...pt 20 factory setting OFF You will then be requested in the display to transmit data after every setting In this case you can start the data transmission right from point 6 Recommendation Buttons Ind...

Page 39: ...motor or switching on the connected light STOP 6 OK 7 OK 8 9 M Confirm data transmission and proceed with the next receiver The programme automatically proposes the next receiver for the data transmi...

Page 40: ...ting Fernotron system you have the following options 1 Registering with a receiver using the SET button see below 2 Registering with a Fernotron radio controlled tubular motor with radio code see page...

Page 41: ...u will be re quested to press the Stop button Perform registration This will take 5 seconds during which there will be a countdown from 5 to 1 in the display ADVICE The receiver acknowledges the succe...

Page 42: ...es Open expert mode It is important to press the buttons in the correct order 1 OK 2 M Select and open the radio code Enter the 5 figure radio code for the tubular motor and confirm each figure with t...

Page 43: ...Select and open data transmission Select group and or receiver In the display you will the re quested to press the Stop button Perform registration This will take 5 seconds during which there will be...

Page 44: ...splay without button lock 2 M OK Switch on the button lock It is important to press the buttons in the correct order 1 OK 2 M The automatic button lock is activated after approx 2 minu tes without any...

Page 45: ...lock on off Setting light function Setting the SU WI transmission time Set the moving text velocity Switch automatic data transmission on and off In expert mode E there are various special functions a...

Page 46: ...1 M 2 3 M OK Calling up expert mode example 4 5 M OK keep presses for approx 2 sec Select expert mode E The menu item flashes Open expert mode It is important to press the buttons in the correct order...

Page 47: ...eceiver names 6 Enter standard switching times 7 Register with receiver and transmit data M Press for 4 sec and return to normal display Commissioning assistant 2 Select group and receiver Select and...

Page 48: ...the radio code you have direct contact with the radio controlled tubular motor You can immediately call up and set the following functions without entering a group or receiver num ber SET function Reg...

Page 49: ...hange direction of rotation OK STOP 4 b M OK IMPORTANT Do NOT select a group or a recei ver Select and open the Direction of rotation in the expert menu Check the direction of rotation of the motor Ch...

Page 50: ...firm group and receiver Set the desired end points ADVICE Keep the button depressed until the desired end position is reached then let go of it again The desired end position is now saved As long as t...

Page 51: ...alteration of the number of groups is possible at any time 10 Define the maximum number of receivers per group 1 to a maximum of 7 receivers per group Select group Set the number of receivers ADVICE S...

Page 52: ...y setting Despite the lack of a DCF signal the summer winter time changeover will be performed in the Progra mming Centre OFF Off ADVICE A change from summer to winter time and vice versa requires the...

Page 53: ...d 14 On and OFF On on OFF off factory setting To protect the Programming Centre from inadvertent adjustment you can activate an automatic button lock 2 minutes without input If the automatic button lo...

Page 54: ...s minutes and confirm Option OFF The SU WI time change over will not be transmitted factory setting 18 OK On and OFF On DCF radio clock on factory setting OFF DCF radio clock off ADVICE Set to OFF if...

Page 55: ...ivers have received the new time Due to structural restrictions to the radio range it can occasionally happen that a receiver does not receive the time In this case you must transmit the summer winter...

Page 56: ...ress for 8 seconds Release the buttons M OK 1 Buttons Indication in the display 2 3 The following messages then appear in quick succession Version number and indication of the top row Indication of al...

Page 57: ...ay 1 STOP 2 3 a 3 b 3 c 4 Select group 5 Set receiver to A for all Example Open all roller shutters Move the roller shutters to the upper end position Stop all roller shutters while they are being rai...

Page 58: ...number of receivers 49 Ambient conditions Device may only be used in dry rooms Dimensions 54 x 142 x 24 mm Technical data battery change If the batteries are almost empty then a battery symbol flashes...

Page 59: ...Toulon Italy 142 Bologna 143 Bolzano 144 Florence 145 Genoa 146 Milan 147 Naples 148 Palermo 149 Rome 150 Torino 151 Venice Ireland 152 Cork 153 Dublin 154 Belfast Latvia 155 Riga Lichtenstein 156 Va...

Page 60: ...adajoz 219 Burgos 220 C ceres 221 Castell n 222 Granada 223 Guadalajara 224 La Coru a 225 L rida 226 Le n 227 Madrid 228 Murcia 229 Oviedo 230 Palma 231 Pamplona 232 San Sebasti n 233 Seville 234 Sant...

Page 61: ...nal influences such as knocks blows or weather Repairs and modifications performed by unauthorised third parties Use of unsuitable accessories or spare parts Damage caused by inadmissible over voltage...

Page 62: ...ions excepted Illustrations for information only RADEMACHER Ger te Elektronik GmbH Co KG Buschkamp 7 46414 Rhede Telefon 49 2872 933 171 Telefax 49 2872 933 251 info rademacher de www rademacher de Se...

Page 63: ...standard switching times Select and open standard switching times 1 M 2 Select group Set opening and closing time 3 OK OK Exit the menu 4 M Select and perform data transmission 5 OK STOP Switch autom...

Page 64: ...TO MANU switchover Numeric display Factory settings Opening time Closing time for group Standard programme 7 00 20 00 G1 G7 Weekly programme 7 00 20 00 G1 G7 Individual day programme 7 00 20 00 G1 G7...