47
EN
17.9.1 Setting the local sunshine position
The sunshine position can only be configured individually for each DuoFern actuator.
Notes on sunshine position
◆
The
running time
must be configured prior to setting the sunshine position (see page
52).
◆
The locally mounted light sensor may not be covered by the roller shutters when they
are moving downwards.
◆
Set the sunshine position in a way that the roller shutters remain above the light sensor.
Otherwise the light sensor cannot correctly measure the brightness level.
1.
Call up the main menu.
2.
Select and open menu
4 [ ] Automated
solar function
.
3.
Select a DuoFern actuator.
a)
Switch the automated solar functions on and
confirm for the selected DuoFern actuator.
4.
Subsequently the
local sunshine position
can be configured.
On
= automated solar functions on
OFF
= automated solar functions off
b)
Store the position of the sun on the DuoFern
actuator and return to the main menu.
a)
Move the roller shutters to the desired
position.