35
i
i
EN
22. Switching reversal of rotation direction on/off
It is not necessary to re-wire the motor if the direction of rotation for the connected motor
is wrong
[ Up ]
key moves the roller shutters downwards and
[ Down ]
key moves the roller
shutters upwards). The direction of the motor can be easily changed using the
reversal of
rotation
direction function.
1.
+
Simultaneously press and hold both buttons for
approx. 4 seconds.
The solar LED flashes red by way of confirmation.
2.
+
Release both buttons.
The direction of rotation is now reversed and stored.
The tubular motor starts up briefly by way of confirmation.
NOTE
The reversal of rotation direction is permanently stored, even in the event of power failure.
23. End point adjustment
NOTE
◆
The end points must be configured in order for the roller shutters to stop at the desired
upper and lower positions. It is imperative that both end points are configured, otherwise
malfunctions may occur.
◆
The end point setting function is only available for RADEMACHER electronic tubular
motors from 2000 onwards.
◆
The end point setting can not be adjusted for tubular motors connected in parallel.