25
Press and hold the
C
or
MAX/MIN/-
button for three seconds to increase
or decrease rapidly.
Press the
ALARM
button to reset current value.
Note
: The rain collector is calibrated at the factory based on the funnel diameter.
The bucket tips every 0.01” of rain (referred to as resolution). The accumulated
rainfall can be compared to a sight glass rain gauge with an aperture of at least 4”.
Note:
that debris and insects can collect inside the tipping mechanism (they
make a good spiders nest). Carefully remove the funnel and inspect the tipping
mechanism for debris prior to calibration.
6) Quick Reference Guide:
Command*
Order
Mode
Default
Settings
SET +
ALARM + 5
seconds
Absolute
Barometer
Offset
0.00
Press
C
or
MAX/MIN/-
to adjust
the absolute pressure up or down.
Note
that you normally not calibrate absolute
pressure unless you have a specific
application example, measuring air density.
SET
Relative
Barometer
Offset
0.00
Press
C
or
MAX/MIN/-
to adjust
the relative pressure offset up or down. See
discussion below on how to calibrate relative
pressure based on conditions at a local
airport.
SET
Wind Gain
1.00
Press
C
button or
MAX/MIN/-
to
adjust the wind gain up or down.
SET
Rain Gain
1.00
Press
C
button or
MAX/MIN/-
to
adjust the rain gain up or down.
SET
Exit
Calibration
Mode
*
SET
+
ALARM
+ 5 seconds = press and hold the
SET
and
ALARM
buttons at the
same time for 5 seconds.
SET
= press (but do not hold) the
SET
button.