Hyper

-

Alerts

 

Hyper

-

Alerts

™ 

can be configured to activate at a given speed 

using the alert settings in the 

HOME

 configuration screen.

 

 

In the example shown, 

Beacon Mode 

is enabled for Alert 2. If a 

car is traveling over 35 MPH, the Alert 2 settings take over and 
the Hyper

-

Alerts

™ 

will activate.

 

 
 

 

 

 

 

 

 

 

 

 

Servicing the Interface Board

 

The only user serviceable parts on the Interface board are the output relay fuses. If a wiring short, or some other 
event occurs causing the fuses to blow, replace with any standard 5 x 20 mm 240 VAC (or greater), 2A, slow

-

blow 

fuse (Part number 

5ST 2

-

R

 or equivalent). 

 

 

Fuses

 

Summary of Contents for TC-800

Page 1: ...1 of 15 Radar Speed Sign Operation Manual_MN0036 v23 01 2005 2023 Radarsign LLC All Rights Reserved TC 800 TC 1100 Radar Speed Sign Operation Manual ...

Page 2: ...the Interface Board pg 14 Warranty pg 15 ______________________________________________________________________________ If you experience any trouble setting up your sign please refer to our Troubleshooting Guide at https www radarsign com troubleshooting guide For additional assistance please call 678 965 4814 and ask for technical support or email customerservice radarsign com Customer Resource ...

Page 3: ...is device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Customer Support Call 678 965 4814 or email customerservice radarsign com Shipping Address 1220 Kennestone Circle Suite 130 Marietta GA 30066 Sales Information Call 678 965 4814 or email info radarsign com RMA Instructions Please make sure to fi...

Page 4: ...thing and equipment To reduce the risk of burns or other acid related injury resulting from exploding batteries Always use the recommended charging systems with this product To reduce the risk associated with contamination of water supplies resulting from improper disposal of batteries containing lead and acid Please dispose of batteries in accordance with all local government laws and regulations...

Page 5: ...adar speed sign for 10 seconds and then reconnect the power to restart the process On some devices you will get a warning that this network does not have an internet connection No internet is required to connect to the radar sign If asked if you wish to stay connected to the network say yes You have successfully connected to your radar sign Once connected open your web browser In the address box a...

Page 6: ...3 01 Basic Sign Setup When the HOME configuration screen opens it will display the current settings of the radar speed sign The alert settings and advanced functions available will vary depending on the your sign model and the sign options you purchased ...

Page 7: ...ign can detect vehicles 3 MPH KPH settings Select the setting for your country s standard Display Configuration 4 Display Enabled Turns the display on or off UNCHECK if you wish to collect traffic statistics in stealth mode to get a baseline of how fast the speeds are on the road in question 5 Speed Limit Enter the speed limit of the road where the sign is installed The speed limit is only used to...

Page 8: ...y will alternate Accessories If you have purchased a sign with strobes select a display from the menu options listed Selection varies by model options purchased Strobe Options Strobe Red Flashes the Red LEDS quickly three times Strobe Blue Flashes the Blue LEDS quickly three times Strobe Red Blue Flashes the Red LEDS three times then the Blue LEDS three times Camera Flash Flashes the White LED onc...

Page 9: ...he timers 3 Possum Switch A vandalism discouraging feature that causes the sign to play dead after it detects a severe impact If this feature is enabled the sign will disable all outward signs of activity display blue blinky etc after detecting an impact equivalent to hitting the sign with a baseball bat The display will remain disabled for 30 minutes and then reboot itself You can manually reboot...

Page 10: ...lay behavior and display content desired for this time period 6 If output relays were purchased with your sign enter the Relay options desired for this time period 7 Be sure to save the settings by clicking the Set Config button This refreshes the screen to allow additional timers to be set You will need to save EACH Timer setting as you go by clicking Set Config button 8 Once the Timer settings a...

Page 11: ...age from 12 VDC 120 VAC across the input screw terminals The input trigger latches on for two seconds which allows flashing beacon lamps to be used to trigger an input event As long as the input sees a voltage above 12V at least once every two seconds the trigger will remain active When using the input trigger with DC sources polarity is important so ensure the positive wire leads to the screw ter...

Page 12: ...acon mode the two output relays will alternate at 1 Hz each relay closed for 0 5 seconds then opened for 0 5 seconds This mode is intended to be used in conjunction with school zone beacon lamps Speed Activated Relays Output relays can be configured to activate at a given speed using the alert settings in the HOME configuration screen In the example shown Output 1 will close whenever the sign dete...

Page 13: ...elay output s on for the entire duration of the timer In the example shown the relays would be in alternating beacon mode every Monday Wednesday and Friday from 8 15 AM to 9 15 AM During any other time the standard configuration will be active Once the timer is configured as desired ensure the timer is enabled by checking the Timer 1 box at the bottom of the HOME configuration screen Click the Set...

Page 14: ...le shown Beacon Mode is enabled for Alert 2 If a car is traveling over 35 MPH the Alert 2 settings take over and the Hyper Alerts will activate Servicing the Interface Board The only user serviceable parts on the Interface board are the output relay fuses If a wiring short or some other event occurs causing the fuses to blow replace with any standard 5 x 20 mm 240 VAC or greater 2A slow blow fuse ...

Page 15: ... is responsible for inbound shipping Radarsign will pay for return shipping to the customer for the entire warranty period if customer is located within North America Customers from a country outside or North America shall pay all shipping charges duties and taxes for products returned to Radarsign LLC for warranty or after warranty repair Radarsign LLC warrants that this product is new Radarsign ...

Reviews: